Occupational radiation exposure and radiation protection practices in interventional radiology and cardiology: A multicenter study in France - 25/06/26

Highlights |
• | Whole-body occupational exposure remains low in radiology and cardiology, whereas extremity and eye lens doses remain substantially high. |
• | Eye lens doses exceed 20 mSv/year in 1.6% of physicians involved in interventional radiology or interventional cardiology. |
• | Invasive coronary angiography shows the highest occupational exposure. |
• | Dosimeter compliance and eye protection use remained suboptimal in physicians involved in interventional radiology or interventional cardiology. |
Abstract |
Purpose |
The purpose of this study was to assess occupational radiation exposure and radiation protection practices among physicians performing interventional radiology and cardiology procedures in France.
Materials and methods |
This retrospective multicenter study included 138 radiologists and 106 cardiologists from 17 French centers between 2019 and 2021. Data regarding passive dosimetry monitoring, radiation protection training, and availability and use of collective and personal protective equipment were collected. Whole-body, extremity, and eye lens dosimetry results were analyzed according to specialty and activity. Only physicians reporting systematic or frequent dosimeter use were included in the quantitative dosimetry analysis.
Results |
Whole-body dosimeters were available for all physicians, whereas extremity and eye lens dosimeters were less often available, particularly in radiology (67% and 27%, respectively). Systematic or frequent dosimeter use was lower for extremity and eye lens monitoring than for whole-body monitoring. Median annual whole-body effective doses remained low in both radiology and cardiology (0.36 and 0.61 mSv/year, respectively), and no physician exceeded the 6 mSv/year threshold corresponding to category B workers. Extremity and eye lens exposures were substantially higher, particularly in vascular radiology and coronary/valvular cardiology. Four out of 244 physicians (1.6%) exceeded the annual eye lens dose limit of 20 mSv/year. Despite broad availability of eye protection equipment, non-use remained frequent among radiologists (35%). Radiation protection training remained heterogeneous across specialties and activities.
Conclusion |
Occupational radiation exposure remained globally low for whole-body exposure but remained substantial for extremities and especially the eye lens. Persistent shortcomings in dosimeter compliance and eye protection use emphasize the need to reinforce radiation protection practices in high-exposure interventional specialties.
Le texte complet de cet article est disponible en PDF.Keywords : Interventional cardiology, Interventional radiology, Occupational exposure, Personal dosimetry, Radiation protection
Abbreviations : CPE, CT, PPE, Q1, Q3
Plan
Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?