Distal radius plate: correlation between the length of distal epiphyseal screws and the width of the watershed line - 08/08/26
, Guillaume Dardenne b, Thibault Poujade c, Marie Vergnenegre a, Hoel Letissier a, bAbstract |
Background |
Accurate distal screw length selection during volar plating of distal radius fractures is important to provide subchondral support while reducing the risk of dorsal cortical penetration. The width of the watershed line may provide an anatomical guide for screw selection.
Methods |
Fifty-one wrist CT scans (35 men, 16 women) were retrospectively analyzed. Watershed line width and distal epiphyseal screw lengths (B1–B5) were measured after virtual placement of fixed-angle volar plates. The relationship between watershed line width and screw length was assessed using linear regression. Conservative screw-length recommendations were derived from the 10th percentile of the observed distributions and rounded down to the nearest available 2-mm screw length.
Results |
Mean watershed line width was 28.6 ± 2.6 mm. Mean screw lengths ranged from 18.5 ± 2.2 mm for B4 to 21.9 ± 1.6 mm for B3. Significant positive correlations were found between watershed line width and screw length for B1 to B4 (r = 0.46–0.65; all p ≤ 0.001), but not for B5 (r = 0.13; p = 0.65). Screw-length distributions differed between standard and large plate subgroups (all p < 0.005). Proposed conservative screw lengths were 18, 18, 20, and 16 mm for standard plates, and 20, 20, 22, 20, and 18 mm for large plates.
Conclusion |
Watershed line width is correlated with distal epiphyseal screw length in fixed-angle volar distal radius plates and may assist conservative initial screw-length selection according to plate size.
Level of evidence |
IV.
Le texte complet de cet article est disponible en PDF.Keywords : Distal radius volar plating (fixed-angle plate/ Newclip Technics©, Initial R™ Xpert 2.4), Watershed line anatomy (volar distal radius ridge/mediolateral width/plate-size selection), Epiphyseal screw-length prediction (B1-B5 distal screws/10th percentile/conservative screw-length recommendations), Dorsal cortical penetration prevention (extensor tendon injury/subchondral support/unicortical fixation), CT-based anatomical modelling (semi-automatic segmentation/STL surface reconstruction/screw-axis measurement), Plate-size–based screw guidance (standard-large plate subgroups/initial screw-length selection/epiphyseal depth coverage)