S'abonner

Méthodologie d’évaluation et de labellisation des dispositifs médicaux numériques (DMN) en chirurgie orthopédique : de la technologie à l’usage - 08/09/26

Assessing and labeling digital medical devices in orthopedic surgery: A comprehensive methodology from technology to practice

Doi : 10.1016/j.rcot.2026.06.002 
Mathieu Grajoszex 1, , Emilie Forestier 1, Lara Mroueh 1, Marc-Olivier Gauci 2, 3
1 Digital Medical Hub, Paris, France 
2 CHU de Nice, Hôpital Pasteur 2, institut universitaire locomoteur et du sport, Nice, France 
3 Université Côte d’Azur, unité ICARE InsermU1091, IBV, Côte d’Azur, France 

Mathieu Grajoszex, Digital Medical Hub, France. Digital Medical Hub France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Tuesday 08 September 2026

Résumé

L’évaluation holistique 360° des dispositifs médicaux numériques (DMN) permet de transformer un processus de décision segmenté en une approche structurée et multi-acteurs. Actuellement, il n’existe pas de méthodologie consensuelle pour apprécier simultanément les dimensions cliniques, médicoéconomiques, organisationnelles, technologiques, réglementaires, environnementales, cognitives et d’équité d’accès. Le cadre réglementaire (marquage CE, Medical Device Reglementation [MDR], AI Act; « Règlement européen sur l’intelligence artificielle (2024) », recommandations HAS/ Food and Drug Administration [FDA]) reste centré sur la conformité technique, la sécurité et la performance analytique, sans considérer les impacts cliniques réels, la charge mentale des équipes et les conditions d’usage des innovations technologiques. Cette fragmentation reflète la complexité de l’écosystème de santé et la diversité des acteurs impliqués, mais constitue un frein majeur à la production de preuves robustes, à la valorisation des innovations pertinentes et, in fine, à leur adoption. Une réponse possible réside dans une analyse multicritère capable d’agréger des impacts hétérogènes en une performance globale pondérée selon les priorités des parties prenantes. Une telle approche couvre notamment les dimensions réglementaire et juridique, clinique et centrée patient, médicoéconomique, organisationnelle, technologique (interopérabilité, cybersécurité), ergonomique et expérience utilisateur, environnementale, cognitive et formative, ainsi que l’équité d’accès. Une expérimentation pilote conduite en 2024 par la société savante Computer Assisted Orthopaedic Surgery (CAOS), en partenariat avec le Digital Medical Hub, illustre la faisabilité de cette démarche en fournissant une évaluation complète d’un outil de planification chirurgicale, faisant émerger à la fois ses forces et ses axes d’amélioration. L’avenir de la santé numérique dépendra de la capacité collective à concilier exigence scientifique, qualité et durabilité, afin que chaque innovation soit non seulement performante, mais également utile, équitable et réellement accessible.

Niveau de preuve

V (Avis d’expert).

Le texte complet de cet article est disponible en PDF.

Summary

The principal value of a holistic 360° assessment of digital medical devices lies in its capacity to transform fragmented decision-making into a structured, multi-stakeholder approach. Currently, no consensus methodology exists for simultaneously evaluating clinical, medico-economic, organizational, technological, regulatory, environmental, cognitive, and healthcare equity dimensions. Current regulatory frameworks (CE marking, European MDR, AI Act, HAS/FDA guidelines) focus exclusively on technical compliance, safety, and analytical performance while neglecting real clinical impacts, organizational consequences, medico-economic value, cognitive burden on care teams, and effects on clinical skill retention. This methodological fragmentation stems not only from the complexity revealed but also from the breadth of digital device applications and the multiplicity of decision-makers – notified bodies, national health authorities, hospital leadership, information technology services, clinical teams, and patients – none sharing identical prerogatives, objectives, or analytical scope, thereby generating major obstacles to evidence generation, innovation valorization, and actual technology adoption. A solution lies in a holistic 360° multi-criteria analysis capable of aggregating heterogeneous impacts into an overall weighted performance reflecting each stakeholder's priorities. Such an approach must encompass eleven dimensions: regulatory/legal, clinical/patient-centered, medico-economic, organizational, technological (cybersecurity and interoperability), user experience/ergonomics, environmental impact, cognitive/educational impacts, and healthcare equity. A pilot study conducted by the CAOS professional society in partnership with the Digital Medical Hub demonstrates feasibility: a comprehensive framework comprising 45 regulatory/legal criteria, 39 clinical/medico-economic/organizational criteria, 165 cybersecurity criteria, 106 UX/UI ergonomics criteria, and 23 corporate social responsibility criteria enables granular and complete evaluation of a surgical planning tool, revealing both strengths and concrete improvement opportunities. The future of digital health depends on our collective ability to balance scientific rigor, quality, and sustainability, ensuring every innovation is not merely performant, but just, useful, and accessible.

Level of evidence

V (Expert opinion).

Le texte complet de cet article est disponible en PDF.

Mots clés : Dispositifs médicaux numériques, Évaluation 360°, Analyse multicritères, Chirurgie orthopédique, Intelligence artificielle

Keywords : Digital medical devices, 360° assessment, Multi-criteria analysis, Orthopedic surgery, Artificial intelligence


Plan


  Ne pas utiliser, pour citation, la référence française de cet article, mais celle de la version anglaise correspondante publiée dans Orthopaedics & Traumatology: Surgery & Research 113/1S (February 2027).


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.