S'abonner

Dimensional and angular agreement of LCD printed zirconia nanohybrid orthodontic brackets with CAD targets in a single build in vitro study - 14/10/26

Doi : 10.1016/j.ortho.2026.101254 
Anthony Allison 1, ⁎ , Rafael Delgado-Ruiz 2 , Duane Shank 1 , Richard Faber 1
1 Department of Orthodontics and Pediatric Dentistry, Stony Brook University School of Dental Medicine, 101 South Drive, Stony Brook, NY 11794, United States 
2 Department of Prosthodontics and Digital Technology, Stony Brook University School of Dental Medicine, 101 South Drive, Stony Brook, NY 11794, United States 

⁎ Anthony Allison, 473 Nassau Blvd, Williston Park, NY 11596, United States. 473 Nassau Blvd Williston Park NY 11596 United States

Summary

Introduction

To quantify the within-build agreement of linear dimensions and slot-wall angulation of custom orthodontic brackets fabricated by LCD-masked vat photopolymerization with their nominal computer-aided design (CAD) targets.

Methods

Fifty brackets were fabricated in one build by one operator using a zirconia nanohybrid photopolymer resin (Rodin Sculpture 2.0). Two examiners measured four outcomes using ImageJ and Geomagic Control X, with three repetitions per examiner and program. Only the 12-reading mean for each specimen and outcome was retained. Means, standard deviations (SDs), confidence intervals (CIs), and conformity with investigator-defined margins (±0.05 mm and ±0.35°) were summarized. These margins were not validated clinical thresholds. The brackets were technical replicates of one build; measurement reliability and between-build reproducibility could not be estimated.

Results

The 50 consolidated specimen-level values yielded means (SDs) of 0.557 (0.015) mm for slot height, 0.711 (0.017) mm for slot depth, 0.999 (0.006) mm for base height, and 7.032° (0.174°) for slot-wall angulation. The corresponding 95% CIs were 0.552–0.561 mm, 0.706–0.716 mm, 0.997–1.000 mm, and 6.982°–7.081°. Specimen-level conformity with the investigator-defined limits was 94%, 94%, 100%, and 96%, respectively.

Conclusions

In this single build completed by one operator, mean linear dimensions and slot-wall angulation were close to the CAD targets. The results describe geometric agreement of averaged measurements within that build; they do not establish measurement reliability, workflow reproducibility, or clinical material suitability.

Le texte complet de cet article est disponible en PDF.

Keywords : Printing, Three-dimensional, Orthodontic brackets, Dimensional measurement accuracy, Vat photopolymerization, Slot angulation, Zirconia nanohybrid


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 24 - N° 4S

Article 101254- décembre 2026 Retour au numéro
Article précédent Article précédent
  • Evaluation of the preventive effects of fluoride varnish, CPP-ACP, nHAp, and self-assembling peptide P11-4 on enamel demineralization around and under clear aligner attachments: An in vitro study
  • Ali Khalil Hasan, Ahmed Mohamed Kamel, Marwa Sameh Shamaa
| Article suivant Article suivant
  • Comparison of cytotoxicity, antibacterial activity and surface roughness, among Ag-, Ag/ZnO-, and Ag/TiO2-coated stainless-steel orthodontic brackets: An in vitro study
  • Mirna Mahmoud Abou El Niaj, Ahmed Mohamed Kamel, Marwa Sameh Shamaa

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.