Abstract

Background

Internal fixation of transcervical femoral neck fractures remains associated with substantial failure and reoperation rates. The Femoral Neck System (FNS) was developed to improve rotational stability while remaining minimally invasive, but comparative data against traditional implants are limited.

Hypothesis

We hypothesised that fixation with the FNS would be associated with lower reoperation rates compared with CS and DHS.

Patients and methods

We performed a retrospective comparative cohort study of adults undergoing fixation of transcervical femoral neck fractures at two centres between 2019 and 2024, with a minimum of 12-months of outcome ascertainment. Data were collected from medical records and radiographs. Negative binomial regression evaluated time to surgery; logistic regression assessed fixation method against union, reoperation and complications, adjusted for age, Charlson Comorbidity Index, Garden classification, side and time to surgery.

Results

After exclusions, 207 patients were analysed (CS 27, DHS 100, FNS 80). Age (CS 54.8, DHS 66.9, FNS 68.2 years; p = 0.02) and Garden distribution (Garden I 7/27 CS, 27/100 DHS, 52/80 FNS; p < 0.001) differed between groups; adjusted analyses accounted for these differences. Reoperation occurred in 37/207 (17.9%): 10/27 (37.0%) CS, 20/100 (20.0%) DHS and 7/80 (8.8%) FNS (p = 0.004). After adjustment, CS remained associated with reoperation versus FNS (OR 5.26, 95% CI 1.53–18.13), whereas DHS did not (OR 1.85, 95% CI 0.65–5.26). Union occurred in 184/207 (88.9%), with no association with fixation method (p = 0.065). Complications occurred in 61/207 (29.5%): 11/27 (40.7%) CS, 32/100 (32.0%) DHS and 18/80 (22.5%) FNS (p = 0.15); higher Garden classification was associated with more complications (Garden II OR 2.58, Garden III OR 3.44; p = 0.037). Time to surgery was shorter with DHS than FNS (IRR 0.49, 95% CI 0.35–0.69; p < 0.001), although the median was 1 day in all groups. Avascular necrosis occurred in 4/80 (5.0%) FNS, 11/100 (11.0%) DHS and 2/27 (7.4%) CS (p = 0.42).

Discussion

Union rates were high across fixation methods. FNS was associated with lower reoperation rates than CS and similar adjusted outcomes to DHS. Prospective studies with patient-reported outcomes are required to confirm these findings.

Level of evidence

III; Retrospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Femoral neck fractures, Dynamic hip screw, Cannulated screws, Femoral neck system, Outcomes


Plan


Crown Copyright © 2026  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.