Accuracy of soft tissue profile predictions using WebCeph and Dolphin software in non-growing skeletal Class II cases treated with upper premolar extractions: A retrospective comparative study - 18/10/26

Doi : 10.1016/j.ortho.2026.101208 
Sara Abou Chedid 1, ⁎ , Marianne Moussallem 2, Roula Akl 1
1 Department of Orthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon 
2 Higher Institute of Public Health, Saint-Joseph University of Beirut, Beirut, Lebanon 

* Sara Abou Chedid, Department of Orthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Damascus Street, Beirut, Lebanon. Department of Orthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut Damascus Street Beirut Lebanon

Summary

Introduction

Aesthetic outcomes are a primary concern for adult orthodontic patients. Clinicians often rely on soft tissue simulation software, such as Dolphin Imaging (D-Tech) and WebCeph (D-Tech), to manage patient expectations. This study aimed to compare the accuracy of these two tools in predicting soft tissue profile changes in non-growing skeletal Class II patients treated with maxillary first premolar extractions.

Methods

A retrospective comparative study was conducted on patients treated by the same practitioner with bilateral maxillary first premolar extractions and maximum anchorage. From a private-practice database of 2535 patients treated between January 2015 and January 2025, 34 met the inclusion criteria after eligibility screening. Pre- and post-treatment lateral cephalometric radiographs and profile photographs were used to generate simulations. Predicted cephalometric measurements from D-Tech and W-Tech were compared with each other and with the actual post-treatment results. Statistical analyses included paired t -tests, one-sample t -tests, Bland-Altman plots, and linear regression.

Results

Thirty-four patients (10 males, 24 females; 35.7 ± 3.5 years) were analysed. Both tools showed a significant discrepancy in the nasolabial angle versus actual results ( P < 0.001). D-Tech differed significantly in the subnasale to Holdaway-line distance (mean difference 0.81 mm [95% CI 0.03 to 1.60]; P = 0.042), while W-Tech differed in upper and lower lip position relative to the True Vertical Line (LL–TVL P = 0.004; UL–TVL P = 0.006). For the remaining parameters, both tools showed good agreement; D-Tech showed a proportional bias for lip–TVL position (greater underestimation at larger values), whereas W-Tech overestimated lower lip thickness.

Conclusion

Both Dolphin Imaging and WebCeph provide clinically applicable predictions for most soft tissue parameters. Several statistically significant lip-position discrepancies were within the range generally considered clinically imperceptible (= 1.5-2.0 mm), whereas the nasolabial angle showed a discrepancy that is both statistically and clinically relevant. Predictions should therefore be interpreted with caution, particularly for parameters prone to systematic bias.

Le texte complet de cet article est disponible en PDF.

Keywords : Class II malocclusion, Cephalometry, Computer simulation, Artificial intelligence


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 24 - N° 4S

Article 101208- décembre 2026 Retour au numéro
Article précédent Article précédent
  • A scoping review of clinical trials involving clear aligner therapy: Study characteristics and outcomes
  • Dalya Al-Moghrabi, Sarah Abu Arqub, Shveta Duggal, Hala Abdullah Alsalman, Padhraig S. Fleming
| Article suivant Article suivant
  • Comparative accuracy of three orthodontic software platforms for mesiodistal tooth-width measurements and bolton analyses in patients with mild to moderate crowding: A retrospective study
  • Hallie Moehring, Qingzhao Yu, Zixin Li, Richard Ballard, Paul Armbruster

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.