S'abonner

Association of bone density, cortical bone thickness, and planned intrabony depth with the accuracy of guided palatal miniscrew insertion in adult patients: A prospective clinical study - 29/10/26

Doi : 10.1016/j.ortho.2026.101258 
Waleed Mustafa Alshannaq ⁎ , Ahmed Mohamed Kamel, Marwa Ali Tawfik
 Mansoura University, Faculty of Dentistry, Department of Orthodontics, Mansoura, Egypt 

⁎ Waleed Mustafa Alshannaq, Mansoura University, Faculty of Dentistry, Department of Orthodontics, Mansoura, Egypt. Mansoura University, Faculty of Dentistry, Department of Orthodontics Mansoura Egypt

Summary

Objective

The primary objective of this study was to evaluate the association between bone density (BD) as the primary predictor and global tip deviation, representing the primary outcome measure of guided miniscrew insertion accuracy. Secondary objectives were to explore the associations of BD with global head deviation and angular discrepancy, and of cortical bone thickness (CBT) and planned intrabony insertion depth with all deviation measures.

Material and methods

This prospective clinical study included 46 self-drilling palatal miniscrews inserted in 23 patients requiring intrusion of maxillary posterior teeth in open bite patients. Virtual miniscrew placement was planned using CBCT and IOS. BD, CBT, and planned intrabony insertion depth were assessed at the insertion sites. Postoperative IOS were obtained using scan bodies attached to the inserted miniscrews, planned and postoperative digital models were superimposed for three-dimensional deviation analysis. Linear deviations were measured at the miniscrew head and tip along the transverse (X), sagittal (Y), and vertical (Z) axes, with global three-dimensional deviations also calculated. Three-dimensional angular discrepancy of miniscrew axes was assessed.

Results

BD demonstrated significant positive correlations with tip global deviation (r = 0.379, P = 0.009), tip vertical deviation (r = 0.302, P = 0.041), and angular discrepancy (r = 0.403, P = 0.005). CBT showed no significant association with any deviation measurements. The mean global deviations were 0.941 ± 0.385 mm and 3.208 ± 1.86 mm at the miniscrew head and tip, respectively. The mean angular discrepancy was 8.585 ± 3.950°. No significant differences were observed between right- and left-side miniscrews ( P > 0.05). No harm was observed during the trial.

Conclusion

Guided palatal miniscrew insertion produced variable transfer deviations, with mean deviations of 0.941 ± 0.385 at the screw head and 3.208 ± 1.863 at the tip. Increased BD was associated with greater tip and angular deviations.

Trial registration

This trial was registered under identification number NCT06757686 .

Le texte complet de cet article est disponible en PDF.

Keywords : Accuracy, Bone density, Cone-beam computed tomography, Orthodontic anchorage, Palatal miniscrews, Surgical guides


Plan


© 2026  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 1

Article 101258- mars 2027 Retour au numéro
Article suivant Article suivant
  • Association of miR-29, miR-155, MMP-9, and MT1-MMP expression with lateral incisor root resorption adjacent to unilaterally impacted maxillary canines: A CBCT-based cross-sectional split-mouth study
  • Muralidharan R, Reema M. Rao, Pradeep V. Samir, Pradeep Subbaiah, Alok Dubey, Rahul Tiwari, Seema Gupta, Manish Sharma

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.