Clinician practices and mechanical properties of orthodontic elastomeric chains: A survey and in vitro comparative study - 07/11/26

Doi : 10.1016/j.ortho.2026.101260 
Yuxiang Tang 1, 3, Jiaqi Liu 1, 3, Jie Xiang 2, Zhenzhen Zhang 1, Xiayanran Wu 1, Xueman Zhou 1, ⁎ , Jun Wang 1, ⁎
1 State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China 
2 Department of Orthodontics, Cranial-Facial Growth and Development Center, National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices& Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, Peking University School and Hospital of Stomatology, Beijing, China 

⁎ Jun Wang, State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China. State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University Chengdu China ⁎⁎ Co-corresponding author.

Summary

Introduction

This study investigated both clinicians’ use and the mechanical properties of orthodontic elastomeric chains, bridging the gap between perception and performance.

Methods

An online cross-sectional survey was conducted among 229 clinicians providing orthodontic treatment. Elastomeric chains of 2–5 loops from five products were tested for force-extension relationship using an Instron machine, and force decay was tracked over 6 weeks under three initial loadings in artificial saliva at 37 °C. Generalized estimating equations with independent working correlation were used to analyse time-by-factor interactions on force decay.

Results

Elastomeric chains were the most commonly used space-closure accessory; 76.8% of clinicians used them based on rough estimates, and 50.0% reported being familiar or completely familiar with their mechanical properties, despite 96.4% acknowledging their importance. The force-extension curves converged when elongation was expressed as percentage of original chain length at stretches below 150%. Approximately 50% of initial force was lost within the first 24 h, followed by a minor decline over 6 weeks. Manufacturer, inter-loop space, and initial loading showed statistically significant but clinically minor effects on force decay.

Conclusions

Most clinicians estimated elastomeric chain forces roughly, and half demonstrated room for improved familiarity with chain mechanics. Under 150% stretch, most tested products generated comparable initial forces at the same percentage elongation. Force decay reached approximately 50% within 24 h, with marginal additional loss over 6 weeks. The replacement interval, rather than product selection, appears to be the more influential factor governing force delivery.

Le texte complet de cet article est disponible en PDF.

Keywords : Elastomers, Orthodontic space closure, Dental stress analysis, Materials testing, Surveys and questionnaires


Plan


© 2026  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 1

Article 101260- mars 2027 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.