Impact of different frequency of cord occlusion mimicking pushing effort on fetal pH variation: an experimental sheep model. - 24/11/26
, L. Ghesquière 1, 2, Y. Hamoud 1, 2, D. Sharma 1, 3, C. Le Ray 4, J. De jonckheere 1, 5, C. Garabedian 1, 2Abstract |
OBJECTIVE |
To evaluate the effect of pushing effort frequency mimicked by cord occlusion on fetal hemodynamics and gasometry in a pregnant ewe model.
STUDY DESIGN |
Nine pregnant ewes were instrumented. Two patterns were compared: (1) an intensive occlusion group: 1 minute of conventional expulsive effort mimicked by cycles of 3 12-second complete cord occlusions interspersed with 12-second partial cord occlusions, with 2 minutes between each cycle; and (2) a moderate occlusion group: 1 minute of expulsive effort mimicked by 2 12-second complete cord occlusions, with 2 minutes between each cycle and no occlusions in 1 out of every 5 cycles.
RESULTS |
At 30 minutes, the lactate levels of the intensive occlusion group were higher than those of the moderate occlusion group (3.23 [2.42; 3.77] vs. 2.37 [1.77; 2.60] mmol/L, respectively; P < .05). At 60 minutes, the mean arterial pressure of the intensive occlusion group was higher than that of the moderate inclusion group (52 [45; 57] vs. 44 [41; 53] mmHg, respectively; P < .05). Other hemodynamic and gasometric measures did not differ between the two groups.
CONCLUSIONS |
In this experimental model, increased lactate levels and mean arterial pressure, indicative of fetal adaptation, were higher with more intensive occlusions.
Le texte complet de cet article est disponible en PDF.Key words : cord compression, ewe, fetal sheep, pH, pushing effort, umbilical cord