Determinants of glycemic control with automated insulin delivery in adults living with type 1 diabetes: A 12-month sub-analysis of the French OB2F Registry - 26/11/26

Doi : 10.1016/j.ando.2026.102600 
Michael Joubert a, ⁎ , Jean-Baptiste Julla b, Eric Renard c, Sandrine Lablanche d, Agnès Sola e, Emmanuel Cosson f, g, Jean-Paul Donnet h, Emmanuel Sonnet i, Anne Vambergue j, Salah Fendri k, Lucien Marchand l, Amal Lemoine m, Laurence Kessler n, Mathieu Giraud o, Isabela Banu p, Elise Pinto Da Rocha q, Camille Vatier r, Françoise Plat s, Aurélie Carlier t, Jean-François Gautier b, Jean-Pierre Riveline b
for

the OB2F Study Group

a Department of Endocrinology, University Hospital of Caen, UNICAEN, Caen, France 
b Department of Endocrinology, Lariboisière Hospital, AP–HP, Université Paris Cité, Paris, France 
c Department of Endocrinology & Diabetes, Montpellier University Hospital, and Institute of Functional Genomics, University of Montpellier, CNRS, INSERM, Montpellier, France 
d Grenoble Alpes university, Endocrinology-Diabetology Department, Grenoble Alpes University Hospital, Grenoble, France 
e Department of Diabetology, Cochin Hospital, AP–HP, Paris, France 
f AP–HP, Department of Endocrinology-Diabetology-Nutrition, Avicenne Hospital, Université Paris 13, Sorbonne Paris Cité, CRNH-IdF, CSO Île-de-France Nord, Bobigny, France 
g Université Sorbonne Paris Nord and Université Paris Cité, INSERM, INRAE, CNAM, Center of Research in Epidemiology and StatisticS (CRESS), Nutritional Epidemiology Research Team (EREN), 93017 Bobigny, France 
h Department of Endocrinology, Clinique de Choisy, Le Gosier, France 
i Department of Endocrinology and Diabetology, University Hospital of Brest, Brest, France 
j Department of Diabetology and Nutrition, University of Lille, Lille, France 
k Department of Diabetology, Endocrinology and Nutrition, University Hospital of Amiens, Amiens, France 
l Department of Endocrinology and Diabetes, Saint Joseph Saint Luc Hospital, Lyon, France 
m Department of Diabetology and Endocrinology, Centre Hospitalier de Vienne, Vienne, France 
n Department of Endocrinology, Diabetes and Nutrition, Strasbourg University Hospitals, Strasbourg, France 
o Department of Endocrinology and Diabetology, Bretagne Atlantique Hospital Center, Vannes, France 
p Department of Diabetology, Endocrinology and Nutrition, Paris Saint-Joseph Hospital, Paris, France 
q Department of Endocrinology, Diabetology and Nutrition, Orléans University Hospital, Orléans, France 
r Endocrine Unit, Reproductive Medicine, Reference Center for Rare Endocrine Diseases of Growth and Development (CRMERC), Endo-ERN, Saint-Antoine Hospital, AP–HP, Sorbonne University, Paris, France 
s Department of Endocrinology and Diabetology, Avignon Hospital Center, AvignonFrance 
t Department of Diabetology and Endocrinology, Bichat Hospital, AP–HP, Paris, France 

⁎ Corresponding author, Diabetes Care Unit, Caen University Hospital, 14033 Caen Cedex 09, France. Diabetes Care Unit, Caen University Hospital Caen Cedex 09 14033 France

Abstract

Objective

To identify baseline determinants of achieving international continuous glucose monitoring (CGM) targets after 12 months of automated insulin delivery (AID) in adults with type 1 diabetes.

Research design and methods

This predefined sub-analysis of the nationwide French OB2F registry included adults with type 1 diabetes initiating MiniMed 780G or Tandem Control-IQ in 2022. Participants required ≥ 14 consecutive days of CGM data at baseline and 12 months. The primary outcome was achievement of combined CGM targets at 12 months, defined as TIR > 70% and TBR < 4%. Baseline predictors were assessed using multivariable logistic regression.

Results

Among 1,058 adults, 43% achieved combined CGM targets at 12 months (52% of MiniMed 780G users and 36% of Tandem Control-IQ users). Better baseline metabolic control, including higher TIR and lower HbA1c, TAR, GMI, and glucose variability, was independently associated with target achievement across both systems. Lower baseline TBR predicted target achievement only in MiniMed 780G users. GRI improved in both systems, from 44.1 ± 19.4 to 30.2 ± 13.6 with MiniMed 780G and from 49.4 ± 20.0 to 36.7 ± 14.9 with Tandem Control-IQ.

Conclusions

Baseline glycaemic profile is the main determinant of achieving international CGM targets after AID initiation in adults with type 1 diabetes, despite substantial improvement in those with poorer baseline control.

Le texte complet de cet article est disponible en PDF.

Keywords : Automated insulin delivery, Time in range, Continuous glucose monitoring, Type 1 diabetes, Real-world evidence


Plan


☆ Previous communication of these results: Oral presentation No 133–Société Francophone du Diabéte (SFD) annuel meeting 2025–Paris–01–04 April 2025.


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 87 - N° 6

Article 102600- février 2026 Retour au numéro
Article précédent Article précédent
  • The tip of the iceberg: Morbidity in polycystic ovary syndrome in reproductive-age women
  • Blandine Courbiere, Eugénie Micolon, Appoline Zimmermann, Pascal Auquier, Julie Berbis, Sandrine Loubière
| Article suivant Article suivant
  • Diabetes in deprived patients
  • Aurélie Bérot, Thi-Lan Huong Do, Hélène Bihan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.