Efficacy of automated insulin delivery after recent pump therapy initiation in type 1 diabetes - 26/11/26
, Marine Halbron b, Isabela Banu c
, Salha Fendri d
, Caroline Sanz e
, Gaétan Prevost f
, Claire Briet g
, Carole Morin h
, Yannis Chartier i
, Justine Lahaye j, ⁎
, Anne Farret a
, Orianne Villard a 
Abstract |
Introduction |
Automated insulin delivery (AID) has been shown to be effective in routine care in type 1 diabetes (T1D). However, its effectiveness without prior insulin pump therapy lasting more than 6 months remains poorly investigated.
Material and methods |
This prospective, multicenter study assessed the 6-month AID effectiveness in patients with T1D for more than one year, not previously treated with an insulin pump, with HbA1c level < 10% and aged over 8 years (y). The primary study endpoint was the change in time in range (TIR, 70–180 mg/dL) from AID initiation to 6 months.
Results |
A total of 43 patients with T1D (38 adults, 5 aged under 18 y) were enrolled in 9 centers. Mean age was 37 ± 16 y, 56% were male, T1D duration was 14 ± 12 years and baseline HbA1c level was 7.6 ± 0.8%. Patients initiated AID (Medtronic® MiniMed™ 780G), after 2.9 ± 1.0 months of non-automated pump therapy. After 6 months of AID ( n = 39), TIR increased by 17.6 ± 11.2% ( P < 0.0001), % time > 180 mg/dL decreased by 15.3 ± 12.1% ( P < 0.0001), % time > 250 mg/dL by 5.9 ± 11.2% ( P = 0.0001), % time < 70 mg/dL by 1.5 ± 3.4% ( P < 0.002), % time < 54 mg/dL by 0.6 ± 2.3% ( P = 0.05). Mean HbA1c level decreased by 0.6 ± 0.6% ( P < 0.0001) and mean sensor glucose by 20.3 ± 37.5 mg/dL ( P = 0.0004). The INSPIRE questionnaire score was unchanged. Adverse events included 2 non-severe ketosis episodes and 2 local skin reactions.
Conclusion |
AID initiation after a short period of pump therapy in T1D patients significantly improved glycemic control over 6 months, with no safety concerns but no measurable improvement in quality of life.