S'abonner

Pulp-to-tooth volume ratio and three-dimensional canine-molar angulation in impacted maxillary canines: A retrospective CBCT study - 27/11/26

Doi : 10.1016/j.ortho.2026.101278 
Marco Farronato 1, 2, ⁎ , Davide Farronato 3, Alessandra Comparini 1, 2, Riccardo Minorini 1, 2, Gennaro Ruggiero 4, Cinzia Maspero 1, 2
1 University of Milan, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Department of Biomedical, Surgical and Dental Sciences, Via della Commenda 9, 20122 Milan, Italy 
2 Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy 
3 University of Insubria, School of Dentistry, Department of Medicine and Surgery, 21100 Varese, Italy 
4 University “Federico II” of Naples, Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics, Scientific Unit of Digital Dentistry, Naples, Italy 

* Marco Farronato, University of Milan, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Department of Biomedical, Surgical and Dental Sciences, Via della Commenda 9, 20122 Milan, Italy. University of Milan, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Department of Biomedical, Surgical and Dental Sciences Via della Commenda 9 Milan 20122 Italy

Summary

Introduction

Maxillary canine impaction is a frequent eruption anomaly in orthodontic patients. Cone-beam computed tomography allows 3D assessment and may provide information beyond 2D measurements. However, internal volumetric features, such as pulp-to-tooth volume ratio, and intra-arch angular relationships have not been investigated.

Material and methods

This retrospective case-control study aims to compare impacted canines using a three-dimensional morphometric approach, including pulp-to-tooth ratio, canine–molar angular divergence, and the difference between three-dimensional and two-dimensional angular measurements. This study included 48 CBCT scans. Thirty-eight patients presented maxillary canine impaction, including 27 unilateral and 11 bilateral cases, for a total of 49 impacted canines. Ten subjects were included as controls. Contralateral erupted canines from unilateral cases were analyzed. Volumes were obtained through semi-automatic segmentation, and the pulp-to-tooth volume ratio was calculated. A novel canine–molar angle was measured in three dimensions and compared with its two-dimensional projection. Paired analyses, linear mixed models, Bland–Altman analysis, and inter-examiner reliability assessment were performed.

Results

In the 21 matched unilateral pairs, impacted group showed a significantly higher pulp-to-tooth volume ratio (mean difference: 0.0065; 95% CI: 0.0021 to 0.0109; P = 0.006). Impacted canines exhibited greater three-dimensional canine–molar angle (mean difference: 22.57̊; 95% CI: 13.64 to 31.50; P < 0.001). Projected two-dimensional measurements showed lower angular deviation in impacted canines. Inter-examiner reliability ranged from good to excellent.

Conclusion

Impacted maxillary canines showed a distinct CBCT-derived morphometric profile, with higher pulp-to-tooth volume ratio and greater three-dimensional canine–molar angular divergence.

Le texte complet de cet article est disponible en PDF.

Keywords : Maxillary canine impaction, CBCT, Pulp-to-tooth volume ratio, Three-dimensional imaging, Orthodontic diagnosis


Plan


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 1

Article 101278- mars 2027 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.