S'abonner

Étude à cinq ans de recul d’une tige anatomique revêtue d’hydroxyapatite - 17/12/08

Doi : 10.1016/j.rco.2008.03.037 
A. Mouttet a, , R. Philippot b, F. Farizon b, P.-H. Vallotton c, N. Ibnou-Zekri c
a Clinique Saint-Roch, chemin du Mas-Anglade, 66330 Cabestany, France 
b Centre d’orthopédie traumatologie, hôpital Bellevue, CHU Saint-Étienne, boulevard Pasteur, 42055 Saint-Étienne cedex 2, France 
c Département recherche et développement, symbios orthopédie SA, avenue des Sciences-1, 1400 Yverdon-les-Bains, Suisse 

Auteur correspondant. Espace méditerranée, 19, avenue du Général-Leclerc, 66000 Perpignan, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 7
Iconographies 4
Vidéos 0
Autres 0

Résumé

Nous avons mené une étude prospective monocentrique sur une série homogène et continue de prothèses totales de hanche anatomiques et non cimentées. Le but de cette étude était de mettre en évidence au recul, l’apport du dessin anatomique de l’implant fémoral avec ses appuis préférentiels, sur les résultats cliniques et radiologiques. Cette série homogène et continue comprenait 176 prothèses totales de hanche, implantées de septembre 1997 à décembre 1998 par une voie antérolatérale par le même chirurgien et toujours en première intention. Nous avons effectué au dernier recul une évaluation clinique comprenant la satisfaction du patient et le score de Harris. Nous avons également réalisé une analyse radiologique, à l’aide des scores de Engh et de Ara, et selon la classification de Brooker, sur les radiographies de face et de profil en postopératoire immédiat et au dernier recul. La survie à cinq ans de la prothèse était de 98,8 %, en prenant comme définition de l’échec la reprise de la prothèse toutes causes confondues. Sur le plan clinique, le score de Harris variait significativement (p<0,0001) de 32,9±1,2 en préopératoire à 93,1±0,8 à la dernière visite de recul. Parmi les items du score, la douleur était le paramètre qui montrait la plus grande amélioration. Les douleurs de cuisse, souvent associées aux tiges sans ciment, restaient à un niveau très bas de 1,3 % à cinq ans de recul. Au niveau radiologique, l’implant fémoral montrait une grande stabilité et un remodelage osseux excellent, illustrés par les scores élevés de Engh et de Ara, respectivement à 20,7±0,5 et 5±0,2. L’usure du polyéthylène, 0,075mm/an, se situait en deçà des taux d’usure habituellement admis pour les cupules métal back comportant un insert polyéthylène. Nous avons observé en revanche un taux d’ossifications hétérotopiques de 65,1 %.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose of the study

We studied a cementless anatomic stem combination with a cementless press-fit cup. The purpose of this work was to assess prospectively in a homogeneous consecutive series of patients, the clinical and radiological outcome of this prosthesis at five years follow-up.

Material and methods

The series included 176 hips with a total hip arthroplasty implanted between September 1997 and December 1998 by the same surgeon through an antero-lateral approach (Watson-Jones). We retained for study first intention implantations for primary or secondary joint degeneration. Fractures and revisions were excluded from the analysis. At last follow-up the survival was 93.2%. Patients were revised clinically (satisfaction Harris score). An independent surgeon unaware of the clinical results performed the radiological analysis (Engh and Ara score, Brooker classification). The Kaplan-Meier method was used for the survival curve expressed with 95% confidence interval and considering revision for all causes as failure.

Results

The five-year survival of the prosthesis was 98.8%. Clinically, the Harris score varied significantly (p<0.0001) from 32.9±1.2 preoperatively to 93.1±0.8 at last follow-up. Among the score items, pain exhibited the greatest improvement since at five years only, 10.2% of patients complained of mild pain. Thigh pain, often associated with cementless stems, was very low, 1.3%. Radiologically, the femoral implant was very stable with excellent bone remodelling as illustrated by the high Engh and Ara scores, 20.7±0.5 and 5±0.2 respectively. Polyethylene wear, 0.075mm/year, was below the usually observed levels. We noted a high rate of heterotopic ossifications, 65.1%, most Brooker I.

Discussion

The SPS stem has shown good results at five years, both clinically and radiographically. The objectives of a stable fixation over time and harmonious remodelling appear to be achieved. These promising results should be reexamined in a series with a longer follow-up.

Le texte complet de cet article est disponible en PDF.

Mots clés : Arthroplastie totale de hanche, Prothèse anatomique, Hanche

Keywords : Total hip arthroplasty, Anatomical prosthesis, Hip


Plan


© 2008  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 94 - N° 8

P. 746-752 - décembre 2008 Retour au numéro
Article précédent Article précédent
  • Étude du remodelage osseux autour de cupules non cimentées en tantale
  • J.-C. Grillo, X. Flecher, J. Bouvenot, J.-N. Argenson
| Article suivant Article suivant
  • Résection fémorale supérieure chez l’enfant polyhandicapé grabataire
  • J. Yankeum, S. Bourelle, G. Lefort, V. Gautheron, B. Al Bitar, J. Cottalorda

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.