S'abonner

IRM dynamique quantitative et localisation du cancer de prostate non palpable - 02/06/09

Doi : 10.1016/j.purol.2009.01.007 
F. Cornud a, ⁎ , F. Beuvon b, F. Thévenin a, L. Chauveinc c, A. Vieillefond b, A. Descazeaux d, T. Flam d
a Service de radiologie B, hôpital Cochin, 27, rue du Faubourg-St-Jacques, 75014 Paris, France 
b Service d’anatomie pathologique, hôpital Cochin, 27, rue du Faubourg-St-Jacques, 75014 Paris, France 
c Centre de radiothérapie, clinique Hartmann, 26, boulevard Victor-Hugo, 92200 Neuilly-sur-Seine, France 
d Service d’urologie, hôpital Cochin, 27, rue du Faubourg-St-Jacques, 75014 Paris, France 

Auteur correspondant. Centre d’imagerie Tourville, 19, avenue de Tourville, 75007 Paris, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 13
Iconographies 9
Vidéos 0
Autres 0

Résumé

Objectif

Étudier si l’IRM de contraste quantitative avec modélisation pharmacocinétique améliore la fiabilité de l’imagerie T2 pour localiser le cancer de prostate non palpable dans la zone périphérique (ZP) et dans la zone de transition (ZT) et estimer son volume.

Matériels et méthodes

Vingt-trois patients (PSA :8,91±6,2ng/ml) avec cancer de prostate non palpable ont bénéficié d’une IRM prostatique endorectale avec imagerie T2 et de contraste avant prostatectomie radicale. Chaque niveau d’évaluation (apex, partie moyenne, base) a été divisée en huit territoires (24 territoires par prostate et 552 territoires pour les 23 patients). La localisation et le volume des foyers tumoraux de plus de 0,2cc présents sur les pièces de prostatectomie ont été rétrospectivement corrélés à leur aspect en IRM sur les 552 territoires étudiés. Les paramètres dynamiques quantitatifs du modèle pharmacocinétique incluaient la perméabilité vasculaire (Ktrans), la concentration maximale de gadolinium ([Gd]) après 60secondes de perfusion, et le lavage du contraste (Kep). Une étude univariée et multivariée a été ensuite réalisée pour déterminer les facteurs prédictifs du cancer.

Résultats

Les valeurs moyennes de Ktrans, [Gd] et Kep étaient significativement supérieures dans les 58 foyers tumoraux supérieurs à 0,2 cm3 de la ZP et de la ZT (p<0,05). La régression logistique pour chaque zone procure une valeur de l’aire sous la courbe ROC de 0,83 pour la ZP et de 0,81 pour la ZT (respectivement, 0,7 et 0,75 pour l’imagerie T2 seule), significative pour la ZP (p<0,002). La sensibilité et la spécificité étaient de 79 et 77 % pour la ZP et de 62,5 et 94 % pour la ZT. Au-delà de 0,2 cm3, la mesure du volume tumoral IRM a montré un écart moyen avec le volume réel de 51±100 % (extrêmes : −145 à +248 %).

Conclusion

Par rapport à l’imagerie T2, la modélisation quantitative de l’IRM dynamique améliore la localisation du cancer de la prostate non palpable de plus de 0,2 cm3, mais sans différence significative pour les cancers de la ZT. Au-delà de ce volume, la corrélation entre le volume tumoral IRM et celui de la pièce est faible.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

To determine whether quantitative dynamic contrast-enhanced MRI improves the performance of T2W–MRI for the localisation of non-palpable prostate cancer (PCa) and for the estimation of tumor volume.

Materials and methods

Twenty-three patients (PSA: 8.91±6.2ng/m) with a non-palpable cancer underwent endorectal MRI with T2W and dynamic contrast enhanced (DCE) imaging before radical prostatectomy. Each level of evaluation (apex, mid-portion, base) was divided in eight areas (24 areas per prostate and 552 areas for the 23 patients). Localisation and volume of tumor foci greater than 0,2cc present on the radical prostatectmoy specimens were retrospectively correlated to their MR appearance on the 552 evaluated areas. The dynamic parameters included capillary permeability (Ktrans), maximum concentration of gadolinium after 60s of perfusion ([Gd]) and wash-out (Kep). Uni- and multivariate analysis were performed to determine which parameters were predictive of PCa.

Results

Mean values of Ktrans, Kep and [Gd] were significantly higher in the 58 tumor foci greater than 0,2 cm3 of the PZ and the TZ (all p<0.05). Logistic regression for each zone provides provided a value of the area under the ROC curve of 0.83 for the PZ and 0.81 for the TZ (0.7 and 0.75, respectively, for the T2W imaging), only significant for the PZ (p<0.002). Sensitivity and specificity were 79 and 77% for the PZ, 62.5 and 94% for the TZ. Above 0,2 cm3, tumor volume on dynamic MR showed a mean difference of 51±100% (range: −145 to +248%).

Conclusions

Quantitative dynamic MRI is more accurate than T2W imaging for tumor localisation of non-palpable cancer greater than 0,2 cm3, but the difference is only significant for the PZ. Above this volume, correlation between tumor volume measured on dynamic MRI and that on the specimen is poor.

Le texte complet de cet article est disponible en PDF.

Mots clés : Cancer de prostate, Localisation, Volume tumoral, IRM dynamique quantitative

Keywords : Prostate cancer, Localisation, Tumor volume, Quantitative dynamic contrast


Plan


 Niveau de preuve : 5.


© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 19 - N° 6

P. 401-413 - juin 2009 Retour au numéro
Article précédent Article précédent
  • Prévalence et composition de la lithiase urinaire dans une population pédiatrique tunisienne
  • A. Alaya, A. Nouri, M.F. Najjar
| Article suivant Article suivant
  • La longueur des biopsies prostatiques conditionne l’identification des éléments capsulaires et périprostatiques
  • F. Mondet, J.-H. Oddou, C. Boyer, L. Corsois, D. Collomb

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.