Les indications actuelles du scanner cardiaque - 23/03/10

Doi : 10.1016/S1878-6480(09)70351-9 
J.-M. Pernès 1, , M. Sirol 2, V. Chabbert 3, L. Christiaens 4, D. Alison 5, M. Hamon 6, C. Caussin 7
1 Sercvice de Radiologie, Hôpital privé d’Antony, 25 rue de la providence, 92160 Antony, France 
2 Département de Radiologie, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris 10, France 
3 Service de Radiologie, CHU Rangueil, 1 avenue Jean Poulhes, TSA 50032, 31059 Toulouse cedex 9, France 
4 Service de Cardiologie, CHU de Poitiers, 2 rue de la Milètrie, BP 577, 86021 Poitiers cedex, France 
5 Service de Radiologie, Hôpital Trousseau, 2 bis boulevard Tonnelé, 37044 Tours cedex, Franc 
6 Service de Cardiologie, CHU de Caen, avenue de la Cote de Nacre, 14033 Caen, France 
7 Service de Cardiologie, Hôpital Marie Lannelongue, 133 avenue de la Résistance, 92350 Le Plessis Robinson, France 

Correspondance.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 0
Vidéos 0
Autres 0

Résumé

Le besoin se faisait prégnant de définir les indications du coroscanner alors même que la technologie multicoupes évolue. Le scanner 64 coupes a démontré son haut niveau de performances diagnostiques vis à vis des lésions ≥ 50%, sur des populations sélectionnées. Il est utilisé actuellement pour sa valeur prédictive négative (96-98%). Ses performances réelles en terme de quantification lésionnelle sont inférieures à la coronarographie avec une tendance à la surestimation du degré de sténose pour les lésions inférieures à 70%.

Pour la détection de la maladie coronaire, le coroscanner doit se positionner, par rapport aux arguments cliniques (probabilité prétest de maladie coronaire) et d’ischémie myocardique fournis par des tests fonctionnels.

Les principales indications appropriées retenues sont :

Dans le cadre de la douleur thoracique aiguë, le coroscanner élimine la maladie coronaire avec une excellente VPN et un bon rapport de vraisemblance négatif (0,05), lorsque l’ECG n’est pas contributif, deux dosages de troponine à 6 heures d’intervalle sont négatifs, chez un patient à faible risque de maladie coronaire.
Dans l’angor stable ou la précordialgie atypique, il est justifié chez les patients à risque faible et intermédiaire dont les tests fonctionnels sont non contributifs ou non réalisables, où que l’ECG est ininterprétable.
Il est un complément à la coronarographie pour l’évaluation morphologique de certaines lésions avant recanalisation et mise en place de prothèse (occlusions longues, lésions proximales impliquant l’artère interventriculaire antérieure et l’artère circonflexe).

Chez les patients sélectionnés, il est réalisable en remplacement à la coronarographie avant une chirurgie valvulaire.

Le texte complet de cet article est disponible en PDF.

Abstract

There is a need to define the current indications for coronary CT angiography (CCTA) even as technology continuously evolves. CCTA using 64 MDCT units has shown to be highly accurate for diagnosis of sténoses ≥ 50% on selected populations. It is currently used for its negative predictive value (96-98%). Stenosis quantification remains inferior to conventional coronary angiography with tendency to overestimate stenoses <70%.

For diagnosis of coronary artery disease, CCTA is considered based on clinical findings (pre-test probability of coronary artery disease) and présence of myocardial ischemia on other functional studies.

The main appropriate indications include:

In the setting of acute coronary syndrome, CCTA excludes coronary artery disease with excellent NPV and good negative likelihood ratio (0.05) when ECG is non-contributory, 2 consecutive troponin levels at 6 hours are negative in a patient with low risk of coronary artery disease.
In the setting of stable angina or atypical precordial chest pain, CCTA is indicated in patients with low to moderate risk when functional tests are non-contributory or unavailable, or ECG is non-interpretable.
CCTA is a complement to coronary angiography for morphological évaluation of some lésions prior to angioplasty and stent placement (long segment occlusion, proximal lésions involving LAD and circumflex arteries).

In selected patients, CCTA may replace coronary angiography prior to valvular surgery.

Le texte complet de cet article est disponible en PDF.

Mots-clés : Scanner coronaire, coronaires, Ischémie myocardique

Key words : Cardiac CTA, Coronary artery disease, Myocardial ischemia


Plan

Plan indisponible

© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 1 - N° 1

P. 13-22 - septembre 2009 Retour au numéro
Article précédent Article précédent
  • Conditions techniques d’utilisation de la tomodensitométrie à rayons X en pathologie cardiaque
  • J.-L. Dehaene, H. Rousseau, V. Chabbert
| Article suivant Article suivant
  • Les conditions techniques d’utilisation de l’IRM cardiaque
  • O. Vignaux, J.-F. Deux, Y. Chabrillat, S. Willoteaux, P.-Y. Marie, F. Laurent, J. Garot

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.