S'abonner

The right ventricular annular velocity reduction caused by coronary artery bypass graft surgery occurs at the moment of pericardial incision - 05/08/11

Doi : 10.1016/j.ahj.2009.11.013 
Beth Unsworth, BSc a, , Roberto P. Casula, MD, FRCS, FECTS b, Andreas A. Kyriacou, MBChB, MRCP a, Hemang Yadav, MA, MBBS a, Andrew Chukwuemeka, LLB, MD, FRCS a, Ashok Cherian, MD b, Rex de Lisle Stanbridge, MD, FRCS b, Thanos Athanasiou, MD, PhD, FETCS a, Jamil Mayet, MD, FRCP a, Darrel P. Francis, MA, MD, FRCP a
a International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College, London 
b St Mary's Hospital, Imperial College Healthcare NHS Trust, Paddington, London 

Reprint requests: Beth Unsworth, BSc, ICCH Building 59-61 North Wharf Road Paddington, W2 1LA London, UK.

Résumé

Background

Right ventricular (RV) long-axis function is known to be depressed after cardiac surgery, but the mechanism is not known. We hypothesized that intraoperative transesophageal echocardiography could pinpoint the time at which this happens to help narrow the range of plausible mechanisms.

Method

Transthoracic echocardiography was conducted in 33 patients before and after elective coronary artery bypass graft. In an intensively monitored cohort of 9 patients, we also monitored RV function intraoperatively using serial pulsed wave tissue Doppler (PW TD) transesophageal echocardiography.

Results

There was no significant difference in myocardial velocities from the onset of the operation up to the beginning of pericardial incision, change in RV PW TD S′ velocities 3% ± 2% (P = not significant).

Within the first 3 minutes of opening the pericardium, RV PW TD S′ velocities had reduced by 43% ± 17% (P < .001). At 5 minutes postpericardial incision, 2 minutes later, the velocities had more than halved, by 54% ± 11% (P < .0001). Velocities thereafter remained depressed throughout the operation, with final intraoperative S′ reduction being 61% ± 11% (P < .0001).

One month after surgery, in the full 33-patient cohort, transthoracic echocardiogram data showed a 55% ± 12% (P < .0001) reduction in RV S′ velocities compared with preoperative values.

Conclusions

Minute-by-minute monitoring during cardiac surgery reveals that, virtually, all the losses in RV systolic velocity occurs within the first 3 minutes after pericardial incision. Right ventricular long-axis reduction during coronary bypass surgery results not from cardiopulmonary bypass but rather from pericardial incision.

Le texte complet de cet article est disponible en PDF.

Plan


© 2010  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 159 - N° 2

P. 314-322 - février 2010 Retour au numéro
Article précédent Article précédent
  • Association of statin prescription with small abdominal aortic aneurysm progression
  • Craig D. Ferguson, Paula Clancy, Bernard Bourke, Philip J. Walker, Anthony Dear, Tim Buckenham, Paul Norman, Jonathan Golledge
| Article suivant Article suivant
  • Relationship between the logistic EuroSCORE and the Society of Thoracic Surgeons Predicted Risk of Mortality score in patients implanted with the CoreValve ReValving System—A Bern-Rotterdam Study
  • Nicolo Piazza, Peter Wenaweser, Menno van Gameren, Thomas Pilgrim, Apostolos Tsikas, Amber Otten, Rutger Nuis, Yoshinobu Onuma, Jin Ming Cheng, A. Pieter Kappetein, Eric Boersma, Peter Juni, Peter de Jaegere, Stephan Windecker, Patrick W. Serruys

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.