S'abonner

Changes in Motor Unit Firing Rate in Synergist Muscles Cannot Explain the Maintenance of Force During Constant Force Painful Contractions - 08/08/11

Doi : 10.1016/j.jpain.2008.06.012 
Paul W. Hodges , Ulysses F. Ervilha , Thomas Graven-Nielsen
 NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury and Health, School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia 
 Center for Sensory-Motor Interaction (SMI), Department of Health Science and Technology, Aalborg University, Aalborg, Denmark 

Address reprint requests to Dr. Paul W. Hodges, NHMRC Centre of Clinical Research Excellence in Spinal Pain, Injury and Health, School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, QLD 4072 Australia

Abstract

The firing rate of low threshold motor units is decreased in constant force contractions during experimental pain. However, as firing rate is a determinant of force, it is unclear how force is maintained. Increased synergist muscle activity may compensate. This was investigated by evaluation of motor unit firing rate in synergist ankle plantar flexor muscles (triceps surae). Single motor unit action potentials were recorded in medial gastrocnemius and soleus muscles with fine wire electrodes in 10 subjects. Gross muscle activity was estimated from surface electromyographic (EMG) recordings. Bolus injections of 5% hypertonic saline were injected into lateral gastrocnemius to induce pain (low intensity, 0.5 mL; high intensity, 1.5 mL). Subjects gently plantar-flexed the ankle to recruit 1 to 4 motor units and performed 3 20-second contractions to this target before, during, and after pain. Firing rate decreased 12% in synergist heads of triceps surae during pain and recovered after pain. Despite reduced firing rate, root-mean-square surface EMG amplitude did not change. The effect of nociceptor stimulation is not restricted to painful muscles but reduces motor unit firing in synergist muscles. Changes in synergist muscles cannot explain the maintenance of muscle force. Maintenance of surface EMG amplitude suggests recruitment of additional motor units.

Perspective

This study showed that activity of synergist muscles can be affected by muscle pain. However, the changes in activity of synergist muscles may not compensate for changes in the painful muscle. This finding provides evidence of more widespread effects of pain on muscle control.

Le texte complet de cet article est disponible en PDF.

Key words : Motor unit, firing rate, muscle pain, motor control


Plan


 Supported by a Fellowship from the National Health and Medical Research Council of Australia.


© 2008  American Pain Society. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 9 - N° 12

P. 1169-1174 - décembre 2008 Retour au numéro
Article précédent Article précédent
  • Sensitization of Primary Afferent Nociceptors Induced by Intradermal Capsaicin Involves the Peripheral Release of Calcitonin Gene-Related Peptide Driven by Dorsal Root Reflexes
  • Dingge Li, Yong Ren, Xijin Xu, Xiaoju Zou, Li Fang, Qing Lin
| Article suivant Article suivant
  • Author Index

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.