S'abonner

Comparison Between Tissue Doppler Imaging and Velocity-Encoded Magnetic Resonance Imaging for Measurement of Myocardial Velocities, Assessment of Left Ventricular Dyssynchrony, and Estimation of Left Ventricular Filling Pressures in Patients With Ischemic Cardiomyopathy - 08/08/11

Doi : 10.1016/j.amjcard.2008.06.064 
Nina Ajmone Marsan, MD a, d, Jos J.M. Westenberg, PhD b, Laurens F. Tops, MD a, Claudia Ypenburg, MD a, Eduard R. Holman, MD, PhD a, Johannes H.C. Reiber, PhD b, Albert de Roos, MD, PhD c, Ernst E. van der Wall, MD, PhD a, f, Martin J. Schalij, MD, PhD a, Jos R. Roelandt, MD, PhD e, Jeroen J. Bax, MD, PhD a,
a Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands 
b Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands 
c Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands 
d Department of Cardiology, IRCCS Policlinico S. Matteo, Pavia, Italy 
e Department of Cardiology, Thoraxcenter, Rotterdam, The Netherlands 
f Interuniversity Cardiology Institute of the Netherlands, Utrecht, The Netherlands 

Corresponding author: Tel: +31-71-5262020; fax: +31-71-5266809

Résumé

Velocity-encoded magnetic resonance imaging (VE-MRI), commonly used to perform flow measurements, can be applied for myocardial velocity analysis, similar to tissue Doppler imaging (TDI). In this study, a comparison between VE-MRI and TDI was performed for the assessment of left ventricular dyssynchrony and left ventricular filling pressures. Ten healthy volunteers and 22 patients with heart failure secondary to ischemic cardiomyopathy underwent both VE-MRI and TDI. Longitudinal myocardial peak systolic and diastolic velocities and time to peak systolic velocity (Ts) were measured with both techniques at the level of left ventricular septum and lateral wall. To quantify left ventricular dyssynchrony, the delay in Ts between basal septum and lateral wall was calculated (SLD) and patients were categorized into 3 groups: minimal (SLD <30 ms), intermediate (SLD = 30 to 60 ms) and extensive (SLD >60 ms) left ventricular dyssynchrony. The ratio of transmitral E wave velocity and mitral annulus septal early velocity (E/E' ratio) was also assessed, and patients were divided into 3 groups: normal (E/E' <8), probably abnormal (E/E' = 8 to 15), and elevated (E/E' >15) left ventricular filling pressures. Excellent correlations were observed for peak systolic velocity and peak diastolic velocity (r = 0.95, p <0.001) measured with TDI and VE-MRI. A small bias (p <0.001) of −1.1 ± 1.1 cm/s for peak systolic velocity and of −0.45 ± 1.03 cm/s for peak diastolic velocity was noted between the 2 techniques. A strong correlation was also noted between Ts measured with TDI and VE-MRI (r = 0.97, p <0.001) without a significant difference. TDI and VE-MRI showed an excellent agreement for left ventricular dyssynchrony and left ventricular filling pressures classification with a weighted κ of 0.96 and 0.91, respectively. In conclusion, TDI and VE-MRI are highly concordant and can be used interchangeably for the assessment of left ventricular dyssynchrony and filling pressures.

Le texte complet de cet article est disponible en PDF.

Plan


 Dr. Marsan is financially supported by the Research Fellowship of the European Society of Cardiology. Dr. Bax has research grants from Medtronic, Boston Scientific, BMS Medical Imaging, St. Jude Medical, and GE Healthcare. Dr. Schalij has research grants from Biotronik, Medtronic, and Boston Scientific.


© 2008  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 10

P. 1366-1372 - novembre 2008 Retour au numéro
Article précédent Article précédent
  • Effects of Group-Based High-Intensity Aerobic Interval Training in Patients With Chronic Heart Failure
  • Birgitta Blakstad Nilsson, Arne Westheim, May Arna Risberg
| Article suivant Article suivant
  • Interventricular Delay Interval Optimization in Cardiac Resynchronization Therapy Guided by Echocardiography Versus Guided by Electrocardiographic QRS Interval Width
  • Matteo Bertini, Matteo Ziacchi, Mauro Biffi, Cristian Martignani, Davide Saporito, Cinzia Valzania, Igor Diemberger, Elena Cervi, Jessica Frisoni, Diego Sangiorgi, Angelo Branzi, Giuseppe Boriani

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.