S'abonner

Haemodynamic Changes During Early Bereavement: Potential Contribution to Increased Cardiovascular Risk - 10/08/11

Doi : 10.1016/j.hlc.2010.10.073 
Thomas Buckley, PhD a, b, Anastasia Susie Mihailidou, PhD b, c, Roger Bartrop, MD c, d, Sharon McKinley, PhD e, f, Christopher Ward, PhD c, g, Marie-Christine Morel-Kopp, PhD c, g, Monica Spinaze, Dip.N b, Geoffrey H Tofler, MBBS, MD b, c,
a Sydney Nursing School, University of Sydney, Australia 
b Department of Cardiology, Royal North Shore Hospital, Sydney, Australia 
c Sydney Medical School, University of Sydney, Australia 
d Department of Psychological Medicine, Royal North Shore Hospital, Australia 
e University of Technology, Sydney, Australia 
f Intensive Care Unit, Royal North Shore Hospital, Australia 
g Kolling Institute, Royal North Shore Hospital, Australia 

Corresponding author at: Department of Cardiology (Level 6), Royal North Shore Hospital, St Leonards 2065, Australia. Tel.: +61 02 99266359; fax: +61 02 99067807.

Résumé

Background

Bereavement is associated with increased cardiovascular risk, particularly in surviving spouses and parents, however the mechanism is not well understood due to limited studies. The purpose of this study was to evaluate haemodynamic changes (blood pressure (BP) and heart rate (HR)), that may contribute to increased cardiac risk in early bereavement.

Methods

We enrolled 80 bereaved individuals and 80 non-bereaved as a reference group. Twenty-four hour ambulatory blood pressure monitoring was performed within two weeks (acute assessment) and at six months following bereavement.

Results

Compared to the non-bereaved, the acutely bereaved had higher 24-hour systolic BP (mean (SE) 130.3 (1.5) vs 127.5 (1.4)mmHg, p=0.03), higher daytime systolic BP (135.6 (1.5) vs 131.6 (1.4)mmHg, p=0.02) and higher daytime systolic load (median % 39.0 vs 29.3, p=0.02). By six months the BP of the bereaved tended to be lower than acute measures. This difference was significant amongst those not taking BP lowering medications for 24-hour systolic BP (126.5 (2.4) vs 129.7 (2.3)mmHg, p=0.04), daytime systolic BP (129.8 (2.1) vs 133.9 (2.0)mmHg, p=0.01) and daytime diastolic pressure (76.7 (1.0) vs 78.9 (0.9)mmHg, p=0.03). Twenty-four hour heart rate was also higher acutely in the bereaved compared with the reference group (74.0 (1.2) vs 71.7 (0.9) b/min, p=0.02); at six months heart rate in the bereaved had fallen to non-bereaved levels (70.4 (0.09), p=0.02).

Conclusion

Early bereavement is associated with increased systolic blood pressure and heart rate. These haemodynamic changes may contribute to a time-limited increase in cardiovascular risk.

Le texte complet de cet article est disponible en PDF.

Keywords : Bereavement, 24-h ambulatory blood pressure, Heart rate, Psychosocial trigger


Plan


© 2010  Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 2

P. 91-98 - février 2011 Retour au numéro
Article précédent Article précédent
  • SCAI Consensus Document on Occupational Radiation Exposure to the Pregnant Cardiologist and Technical Personnel
  • Patricia J.M. Best, Kimberly A. Skelding, Roxana Mehran, Alaide Chieffo, Vijayalakshmi Kunadian, Mina Madan, Ghada W. Mikhail, Fina Mauri, Saeko Takahashi, Junko Honye, Rosana Hernández-Antolín, Bonnie H. Weiner, on behalf of the Women in Innovations (WIN) group of the Society of Cardiac Angiography and Intervention
| Article suivant Article suivant
  • The Australian and New Zealand Cardiac Pacing and Implantable Cardioverter-Defibrillator Survey: Calendar year 2009
  • Harry G. Mond, Ralph M.L. Whitlock

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.