S'abonner

Needle-based confocal laser endomicroscopy to assess liver histology in vivo - 11/08/11

Doi : 10.1016/j.gie.2010.10.002 
Albert Mennone, MS, Michael H. Nathanson, MD, PhD
 Current affiliations: Digestive Diseases Section, Yale University School of Medicine, New Haven, Connecticut, USA 

Reprint requests: Michael H. Nathanson, MD, PhD, Section of Digestive Diseases, Yale University School of Medicine, 300 Cedar Street, Room TAC S241D, New Haven, CT 06520-8019

Résumé

Background

Confocal endomicroscopy enables histopathology of the GI lumen to be observed in vivo. Recent prototypes of a confocal miniprobe are thin enough to be introduced through a needle.

Objective

To evaluate the ability of needle-based confocal laser endomicroscopy to distinguish between normal and cirrhotic liver tissue in vivo in a rat model.

Design

Feasibility study, nonsurvival animal experiments.

Setting

Academic research facility.

Intervention

Three normal control and 4 cirrhotic rats were examined under general anesthesia. The liver was exposed by laparotomy and imaged by using 3 different prototypes of confocal miniprobes, with 0, 50, and 100 μm working distances. Images were acquired on the surface of the liver capsule and through a 19-gauge needle inserted into the liver parenchyma. Real-time sequences were recorded after intravenous injection of fluorescein. Biopsy specimens were taken for standard histopathology.

Main Outcome Measurements

Confocal microscopic images of the surface and interior of livers in normal and cirrhotic rats.

Results

Miniprobes with 50 or 100 μm working distances identified cords of hepatocytes radiating toward central venules in normal livers and distorted hepatic architecture in cirrhotic livers when the miniprobes were either placed on the liver capsule or inserted into the parenchyma. The miniprobe with a 0 μm working distance identified a novel reticular pattern on the liver surface that was detected only in cirrhosis. Like the 2 longer-working-distance probes, this probe also identified cords of hepatocytes radiating toward central venules in normal livers and distorted hepatic architecture in cirrhotic livers, but this occurred only when the probe was inserted into the parenchyma.

Limitations

Data were assessed in an experimental animal setting, confocal imaging was performed invasively during laparotomy, only 1 model of cirrhosis was used, and no noncirrhotic liver diseases were examined.

Conclusion

Needle-based confocal laser endomicroscopy provides sufficient detail to distinguish normal from cirrhotic livers in a rat model. This innovative, minimally invasive technique has the potential to provide real-time identification of liver histology during EUS or natural-orifice transluminal endoscopic surgery procedures.

Le texte complet de cet article est disponible en PDF.

Abbreviations : BDL, eCLE, H&E, nCLE, NOTES, pCLE


Plan


 DISCLOSURE: Mauna Kea Technologies, Paris, France, provided needle-based confocal laser endomicroscopy probes for this study. This work was supported by National Institutes of Health grants DK34989, DK45710, DK61747, and DK57751. The authors disclosed no other financial relationships relevant to this publication.


© 2011  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 73 - N° 2

P. 338-344 - février 2011 Retour au numéro
Article précédent Article précédent
  • Application of the newly developed stents in the treatment of benign cardia stricture: an experimental comparative study
  • Yue-Qi Zhu, Ying-Sheng Cheng, Feng Li, Ming-Hua Li, Jun-Gong Zhao, Ni-Wei Chen
| Article suivant Article suivant
  • Continuing Medical Education Exam: February 2011
  • Raquel E. Davila, Jeffrey H. Lee, William Ross, Shou-Jiang Tang, G.S. Raju, Glenn M. Eisen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.