S'abonner

High-intensity interval training may reduce in-stent restenosis following percutaneous coronary intervention with stent implantation : A randomized controlled trial evaluating the relationship to endothelial function and inflammation - 12/08/11

Doi : 10.1016/j.ahj.2009.08.021 
Peter S. Munk, MD a, b, , Eva M. Staal, MD, PHD a, b, Noreen Butt, MD a, Kjetil Isaksen, MD a, Alf I. Larsen, MD, PHD a, b
a Department of Cardiology, Stavanger University Hospital, Stavanger, Norway 
b Institute of Medicine, University of Bergen, Bergen, Norway 

Reprint Requests: Peter Scott Munk, MD, Stavanger University Hospital, Department of Cardiology, Postbox 8100, 4068 Stavanger, Norway.

Résumé

Background

High-intensity interval training has been shown to be superior to moderate continuous exercise training in improving exercise capacity and endothelial function in patients with coronary artery disease. The objective of this study was to evaluate this training model on in-stent restenosis following percutaneous coronary intervention for stable or unstable angina.

Methods and Results

We prospectively randomized 40 patients after percutaneous coronary intervention with implantation of a bare metal stent (n = 30) or drug eluting stent (n = 32) to a 6-month supervised high-intensity interval exercise training program (n = 20) or to a control group (n = 20). At six months, restenosis, measured as in-segment late luminal loss of the stented coronary area, was smaller in the training group 0.10 (0.52) mm compared to the control group 0.39 (0.38) mm (P = .01). Reduction of late luminal loss in the training group was consistent with both stent types. Peak oxygen uptake increased in the training and control group by 16.8% and 7.8%, respectively (P < .01). Flow-mediated dilation improved 5.2% (7.6) in the training group and decreased -0.1% (8.1) in the control group (P = .01). Levels of high-sensitivity C-reactive protein decreased by -0.4 (1.1) mg/L in the training group and increased by 0.1 (1.2) mg/L in the control group (P = .03 for trend).

Conclusions

Regular high-intensity interval exercise training was associated with a significant reduction in late luminal loss in the stented coronary segment. This effect was associated with increased aerobic capacity, improved endothelium function, and attenuated inflammation.

Le texte complet de cet article est disponible en PDF.

Plan


 www.ClinicalTrials.gov Identifier: NCT00469950.


© 2009  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 158 - N° 5

P. 734-741 - novembre 2009 Retour au numéro
Article précédent Article précédent
  • Design and rationale of the Evaluation of M118 IN pErcutaNeous Coronary intErvention (EMINENCE) trial
  • Chiara Melloni, Ian Fier, James Roach, Andrzej S. Kosinski, Samuel Broderick, Kristina Sigmon, Shelley Myles, Richard C. Becker, Sunil V. Rao, on behalf of the EMINENCE Investigators
| Article suivant Article suivant
  • Reporting and representation of race/ethnicity in published randomized trials
  • Jeffrey S. Berger, Chiara Melloni, Tracy Y. Wang, Rowena J. Dolor, Camille G. Frazier, Zainab Samad, Eric D. Peterson, Daniel B. Mark, L. Kristin Newby

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.