S'abonner

Comparison of Two- and Three-Dimensional Echocardiography With Sequential Magnetic Resonance Imaging for Evaluating Left Ventricular Volume and Ejection Fraction Over Time in Patients With Healed Myocardial Infarction - 15/08/11

Doi : 10.1016/j.amjcard.2006.08.026 
Carly Jenkins, MSc, Kristen Bricknell, MSc, Jonathan Chan, MD, Lizelle Hanekom, MD, Thomas H. Marwick, MD, PhD
University of Queensland, Brisbane, Queensland, Australia. 

Corresponding author: Tel: 61-7-3240-5340; fax: 61-7-3240-5399.

Résumé

Echocardiographic follow-up of left ventricular (LV) volumes is difficult because of the test–retest variation of 2-dimensional echocardiography (2DE). We investigated whether the accuracy and reproducibility of real-time 3-dimensional echocardiography (RT3DE) would make this modality more feasible for serial follow-up of LV measurements. We performed 2DE and RT3DE and cardiac magnetic resonance imaging (MRI) in 50 patients with previous infarction and varying degrees of LV function (44 men; 61 ± 11 years of age) at baseline and after 1-year follow-up. Images were obtained during breath-hold and measurements of LV volumes and ejection fraction were made offline. Over follow-up, end-diastolic volume decreased from 192 ± 53 to 187 ± 60 ml (p <0.01), end-systolic volume decreased from 104 ± 51 to 95 ± 53 ml (p <0.01), and ejection fraction increased from 48 ± 12% to 51 ± 12% (p <0.01). MRI showed that LV mass shrank from 183 ± 39 to 182 ± 37 g (p <0.01). The correlation between change in RT3DE and change in MRI was greater than the correlations of 2DE with MRI for measurement of end-diastolic volume (r = 0.47 vs 0.02, p <0.01), end-systolic volume (r = 0.44 vs 0.17, p <0.01), and ejection fraction (r = 0.58 vs −0.03, p <0.01). The change in end-diastolic volume between baseline and follow-up with RT3DE (−4 ± 20, p <0.01) was similar to that with MRI but was unrecognized by 2DE (4 ± 19, p = 0.09). There was good test–retest and inter- and intraobserver correlation within RT3DE for volumes, ejection fraction, and mass. In conclusion, if sequential measurement of LV volumes is used to guide management decisions, 3DE appears preferable to 2DE.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 3

P. 300-306 - février 2007 Retour au numéro
Article précédent Article précédent
  • Changing Capacity of Electrocardiographic Ventricular Repolarization in Post-Myocardial Infarction Patients With and Without Nonfatal Cardiac Arrest
  • Jere Järvenpää, Lasse Oikarinen, Petri Korhonen, Heikki Väänänen, Lauri Toivonen, Matti Viitasalo
| Article suivant Article suivant
  • Left Ventricular Diastolic Filling Pattern at Doppler Echocardiography and Apoptotic Rate in Fatal Acute Myocardial Infarction
  • Gianfranco Sinagra, Rossana Bussani, Antonio Abbate, Maddalena Piro, Giuseppe G.L. Biondi-Zoccai, Michael C. Kontos, Gastone Sabbadini, Elena Barresi, Filippo Crea, Luigi M. Biasucci, Aneta Aleksova, Bruno Pinamonti, Furio Silvestri, George W. Vetrovec, Alfonso Baldi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.