Diastolic function assessment in clinical practice: The value of 2-dimensional echocardiography - 16/08/11
, James B. Seward, MD a, Beatrix Buschenreithner b, Jutta Bergler-Klein, MD b, Maria Heger, MD b, Ursula Klaar, MD b, Thomas Binder, MD b, Gerald Maurer, MD b, Manfred Zehetgruber, MD bRésumé |
Background |
The aim of this study was to test the hypothesis that diastolic dysfunction associated with increased filling pressures is unlikely in a structurally normal heart and to assess whether 2-dimensional echocardiography can facilitate diastolic function grading in a clinical setting.
Methods |
Consecutive patients referred for transthoracic echocardiography received a comprehensive Doppler echocardiographic evaluation of diastolic function and measurements of left ventricular ejection fraction (EF) by biplane Simpson's method, left atrial volume index (LAVI) by area-length method, and interventricular septal thickness (IVS) from 2-dimensional images. Patients with atrial fibrillation, cardiac pacemaker, severe mitral regurgitation, or mitral prosthesis were excluded.
Results |
Of 187 patients, 38 had normal diastolic function and 77 had grade I; 54, grade II; and 18, grade III diastolic dysfunction. The presence of any 2-dimensional abnormality (EF <55%, IVS ≥14 mm, LAVI ≥40 mL/m2) identified any diastolic dysfunction (grade I-III) with 92.6% sensitivity and 92.1% specificity. In a receiver operating characteristic analysis to predict any diastolic dysfunction, the areas under the receiver operating characteristic curve for EF, IVS, and LAVI and the sum of all 3 abnormalities were 0.69, 0.81, 0.87, and 0.95 (all P < .0001), respectively. Among all patients with at least one abnormality, the probability of diastolic dysfunction was 97.9% (138/141). Interpretation of 2-dimensional abnormalities together with the mitral inflow pattern resulted in correct diastolic function grading in 98.4% (184/187).
Conclusions |
Structural abnormalities on 2-dimensional echocardiography are not only statistically associated with diastolic dysfunction, but the combination of LAVI, EF, and IVS is of practical value for diastolic function grading. The presence of any such 2-dimensional abnormality should be considered indicative of diastolic dysfunction.
Le texte complet de cet article est disponible en PDF.Plan
| Dr Osranek was supported by postdoctoral fellowships from the American Heart Association (0525771Z), Dallas, TX, and the Austrian Science Fund (Schrödinger Stipend, J2289-B02), Vienna, Austria. |
Vol 154 - N° 1
P. 130-136 - juillet 2007 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?