S'abonner

Real-Time Ultrasonographically-Guided Internal Jugular Vein Catheterization in the Emergency Department Increases Success Rates and Reduces Complications: A Randomized, Prospective Study - 17/08/11

Doi : 10.1016/j.annemergmed.2006.01.011 
Julie Leung, MBBS, BSc a, Martin Duffy, MBBS a, b, , Andrew Finckh, MBBS, BA a, b
a St Vincent’s Hospital, Darlinghurst, Sydney, New South Wales, Australia 
b University of New South Wales New South Wales, Australia, Kensington, New South Wales, Australia. 

Address for correspondence: Martin Duffy, MBBS, Emergency Department, St Vincent’s Hospital, Darlinghurst, Sydney, NSW, Australia; 61-02-8382-2040, fax 61-02-9360-1988

Résumé

Study objective

We compare real-time ultrasonographic guidance and the traditional landmark technique for the insertion of internal jugular vein catheters in an emergency department (ED) setting.

Methods

This was a prospective, randomized, clinical study performed in a tertiary ED between August 2003 and May 2005 on patients requiring central venous access. Ultrasonographically guided catheters were inserted under real time using the Sonosite ultrasonographic system with a 10 to 5 MHz 38-mm linear array transducer. Standardized data were collected on operator experience, method of insertion, reason for central venous access, and comorbidities. Outcome measures included successful insertion of an internal jugular vein catheter, number of attempts, access times, and complications.

Results

One hundred thirty patients were enrolled. Cannulation of the internal jugular vein was successful in 61 of 65 patients (93.9%) using ultrasonography and in 51 of 65 patients (78.5%) using the landmark technique, a significant difference of 15.4% (P=.009, 95% confidence interval [CI] 3.8% to 27.0%). Fifty of 61 (82.0%) of the successful ultrasonographically guided catheters were inserted on the first attempt compared with 36 of 51 (70.6%) of the successful landmark catheters. Mean access times to venipuncture and successful insertion were 138 and 281 seconds by ultrasonographic guidance and 132 and 271 seconds by the landmark technique. There was a 10.8% complication rate, with 11 complications (16.9%) in the landmark group and 3 (4.6%) in the ultrasonographic group, a difference of 12.3% (95% CI 1.9% to 22.8%).

Conclusion

Ultrasonographically guided internal jugular vein catheterization in the ED setting was associated with a higher successful insertion rate and a lower complications rate.

Le texte complet de cet article est disponible en PDF.

Plan


 Supervising editor: Richard M. Levitan, MD
Author contributions: AF conceived the study. JL, AF, and MD designed the trial. JL was responsible for data collection, and MD analyzed the data. JL drafted the manuscript, and MD contributed substantially to its revision. MD takes responsibility for the paper as a whole.
Funding and support: This study did not receive any outside funding or support.
Reprints not available from the authors.


© 2006  American College of Emergency Physicians. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48 - N° 5

P. 540-547 - novembre 2006 Retour au numéro
Article précédent Article précédent
  • Did you know?
| Article suivant Article suivant
  • Ultrasonographic Guidance for Internal Jugular Vein Cannulation: An Educational Imperative, A Desirable Practice Alternative
  • Alfredo Sabbaj, Jerris R. Hedges

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.