Résumé

Background

Patients with advanced heart disease are at risk from sudden death; however, benefit from implantable cardioverter defibrillators (ICDs) may be limited as a result of early mortality from other causes. The objective of this study was to develop a model to predict mortality within the first year after ICD implantation.

Methods and Results

A retrospective analysis was performed of 469 consecutive patients who underwent ICD implantation at a single tertiary-care center from 1999 to 2002. Vital status was determined from the Social Security Death Index. Patients were randomized into prediction and validation cohorts. A risk score was derived from the prediction cohort by multivariate logistic regression and applied to the validation cohort. One point was assigned for each variable in the risk score (age >80 years, history of atrial fibrillation, creatinine >1.8 mg/dL, New York Heart Association class III or IV). One-year mortality significantly increased with increasing risk score in both the prediction and validation cohorts. Validation cohort mortality was 3.4% for 0 points, 4.3% for 1 point, 17% for 2 points, and 33% for ≥3 points (P for trend <.0001). A risk score ≥2 predicted a 1-year mortality rate of 21%, whereas a risk score <2 predicted a mortality rate of 4% at 1 year (P < .0001).

Conclusion

A risk score using simple clinical criteria may identify patients at high risk of early mortality after ICD implantation. This may be helpful in consideration of ICD risk/benefit for individual patients. Further studies conducted in a prospective manner using these clinical criteria are warranted.

Le texte complet de cet article est disponible en PDF.

Plan


 The authors have no conflicts of interest to disclose.


© 2006  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 151 - N° 2

P. 397-403 - février 2006 Retour au numéro
Article précédent Article précédent
  • Prediction of the recurrence of atrial fibrillation after cardioversion in the Atrial Fibrillation Follow-up Investigation of Rhythm Management (AFFIRM) study
  • Merritt H. Raitt, Annabelle S. Volgman, Robert G. Zoble, Lyne Charbonneau, Farooq A. Padder, Gilles E. O'Hara, David Kerr, the AFFIRM Investigators g
| Article suivant Article suivant
  • Meta-analysis of comparative diagnostic performance of magnetic resonance imaging and multislice computed tomography for noninvasive coronary angiography
  • Joanne D. Schuijf, Jeroen J. Bax, Leslee J. Shaw, Albert de Roos, Hildo J. Lamb, Ernst E. van der Wall, William Wijns

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.