Effect of defibrillation testing on management during implantable cardioverter-defibrillator implantation - 18/08/11

Doi : 10.1016/j.ahj.2006.06.025 
Peter Leong-Sit, MD FRCPC, Lorne J. Gula, MD MSc FRCPC , Pantelis Diamantouros, MD FRCPC, Andrew D. Krahn, MD FRCPC FACC, Allan C. Skanes, MD FRCPC, Raymond Yee, MD FRCPC FACC, George J. Klein, MD FRCPC FACC
Division of Cardiology, University of Western Ontario, London, Ontario, Canada 

Reprint requests: Lorne J. Gula, London Health Sciences Centre, Arrhythmia Service, 339 Windermere Road, London, Ontario CANADA, N6A 5A5.

Résumé

Background

Verification of defibrillation efficacy by defibrillation threshold (DFT) testing during implantable cardioverter-defibrillator implantation is the current standard. Generally, defibrillation of ventricular fibrillation at 10 J below the maximum output of a device is felt to establish an adequate safety margin. Nonetheless, DFT testing adds to cost and carries some potential for morbidity, whereas its impact on outcomes in the modern era of defibrillator technology is unclear. We aimed to determine the frequency that DFT testing resulted in a change at device implant and to identify clinical and echocardiographic predictors of the need for DFT testing.

Methods

We reviewed all implantable cardioverter-defibrillators that were implanted at the London Health Sciences Centre (Ontario, Canada) from June 1999 to August 2003 and used multivariate analysis to determine variables associated with DFT test failures and elevated DFT values. When a defibrillation failure was not observed, a lowest energy to defibrillate (LED) was recorded.

Results

Among 168 implants, DFT testing was successful with a minimum 10-J safety margin in 152 (90%), whereas the remaining 16 required changes at device implant. In a multivariate analysis, use of amiodarone was independently associated with DFT failure (odds ratio, 4.6; 95% confidence interval, 1.2-17.0). Significantly higher mean DFT/LED values were observed among patients on amiodarone (1.36 J; P = .0041). Those with nonischemic cardiomyopathy had a higher mean DFT/LED compared with those with ischemic cardiomyopathy (1.44J; P = .028).

Conclusions

Use of amiodarone is associated with a 4-fold increase in risk of DFT failure and subsequent need for changes at implant to achieve a safe threshold. Defibrillation threshold testing appears to be most useful for patients taking amiodarone.

Le texte complet de cet article est disponible en PDF.

Plan


© 2006  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 152 - N° 6

P. 1104-1108 - décembre 2006 Retour au numéro
Article précédent Article précédent
  • Influence of age, sex, and atrial fibrillation recurrence on quality of life outcomes in a population of patients with new-onset atrial fibrillation: The Fibrillation Registry Assessing Costs, Therapies, Adverse events and Lifestyle (FRACTAL) study
  • Matthew R. Reynolds, Tara Lavelle, Vidal Essebag, David J. Cohen, Peter Zimetbaum
| Article suivant Article suivant
  • Plasminogen activator inhibitor type 1 gene polymorphisms and haplotypes are associated with plasma plasminogen activator inhibitor type 1 levels but not with myocardial infarction or stroke
  • Jingzhong Ding, Barbara J. Nicklas, Margaret D. Fallin, Nathalie de Rekeneire, Stephen B. Kritchevsky, Marco Pahor, Nicolas Rodondi, Rongling Li, Joseph M. Zmuda, Tamara B. Harris

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.