S'abonner

Morphologic analysis of stage 3 and stage 4 macular holes: Implications for treatment - 18/08/11

Doi : 10.1016/j.ajo.2004.07.038 
Jon Wender, MD a, Tomohiro Iida, MD b, c, Lucian V. Del Priore, MD, PhD c, d,
a Albert Einstein College of Medicine, Bronx, New York, USA 
b Department of Ophthalmology, Fukushima Medical University School of Medicine, Fukushima, Japan 
c Vitreous-Retina-Macula Consultants of New York and LuEster T. Mertz Retinal Research Center, Manhattan Eye, Ear, and Throat Hospital, New York, New York, USA 
d Department of Ophthalmology, Harkness Eye Institute, Columbia University, New York, New York, USA 

*Inquiries to Lucian V. Del Priore, MD, PhD, Robert L. Burch III Scholar, Department of Ophthalmology, Harkness Eye Institute of Columbia University, 635 West 165th St, New York, NY 10032; fax: (212) 342-1724

Résumé

Purpose

To determine whether the observed anatomy of macular holes can be explained by a hydrodynamic model in which fluid flow through the hole is balanced by fluid pumping across the retinal pigment epithelium. We use this model to draw conclusions about the possible role of vitreomacular traction in determining the anatomy of macular holes and their resolution after vitreous surgery.

Design

Cross sectional.

Methods

Retrospective study in a clinical practice. The study included 42 eyes of 42 patients with a stage 3 or 4 macular hole (Gass classification). We measured the radius of the macular hole and the radius of the surrounding cuff of subretinal fluid from color or red-free fundus photographs and determined the relationship between these two variables.

Results

The mean age of the patients was 68.0 ± 7 years (range, 51 to 80). Twenty-five patients had stage 3 macular holes and 17 patients had stage 4 macular holes. The neurosensory detachment radius was related to the square of the macular hole radius for stage 3 and stage 4 holes, with no significant difference between the stage 3 and stage 4 linear trend lines (P = .999). There was no correlation between patient age and the area of the macular hole (r = 0.0645) or neurosensory detachment plus hole (r = 0.156) over the range of age in this study. However, the area of the doughnut-shaped cuff of subretinal fluid increased with increasing patient age (P = .0493), thus suggesting an age-dependent decline in the pumping ability of the retinal pigment epithelium.

Conclusions

Our data are consistent with a hydrodynamic model in which macular hole anatomy is determined by a balance between fluid flow through the hole and fluid outflow across the retinal pigment epithelium. Because stage 3 and stage 4 macular holes exhibit a similar relationship between the size of the macular hole and the size of the cuff of subretinal fluid around the hole, simple relief of vitreomacular traction would not lead to resolution of the subretinal fluid cuff unless it is accompanied by a reduction in hole diameter due to approximation of wound edges.

Le texte complet de cet article est disponible en PDF.

Plan


 Supported in part by the Eye Surgery Fund, the Robert L. Burch III Fund, the Macula Foundation, and Research to Prevent Blindness, Inc, New York, New York.


© 2005  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 139 - N° 1

P. 1-10 - janvier 2005 Retour au numéro
Article suivant Article suivant
  • Orbital exenteration: One size does not fit all
  • Guy J. Ben Simon, Robert M. Schwarcz, Raymond Douglas, Danica Fiaschetti, John D. McCann, Robert A. Goldberg

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.