Improved Glottic Exposure With the Video Macintosh Laryngoscope in Adult Emergency Department Tracheal Intubations - 20/08/11

Doi : 10.1016/j.annemergmed.2010.01.033 
Calvin A. Brown, MD a, b, , Aaron E. Bair, MD c, Daniel J. Pallin, MD, MPH a, b, d, Erik G. Laurin, MD c, Ron M. Walls, MD a, b

National Emergency Airway Registry (NEAR) Investigators

a Department of Emergency Medicine, Brigham and Women's Hospital, Boston, MA 
b Division of Emergency Medicine, Harvard Medical School, Boston, MA 
c Department of Emergency Medicine, University of California–Davis, Sacramento, CA 
d Division of Emergency Medicine, Children's Hospital Boston, Boston, MA 

Address for correspondence: Calvin A. Brown III, MD, 75 Francis St, NH-312D, Boston, MA 02115; 617-732-8908, fax 617-713-3060

Résumé

Study objective

Glottic visualization with video is superior to direct laryngoscopy in controlled operating room studies. However, glottic exposure with video laryngoscopy has not been evaluated in the emergency department (ED) setting, where blood, secretions, poor patient positioning, and physiologic derangement can complicate laryngoscopy. We measure the difference in glottic visualization with video versus direct laryngoscopy.

Methods

We prospectively studied a convenience sample of tracheal intubations at 2 academic EDs. We performed laryngoscopy with the Karl Storz Video Macintosh Laryngoscope, which can be used for conventional direct laryngoscopy, as well as video laryngoscopy. We rated glottic visualization with the Cormack-Lehane (C-L) Scale, defining “good” visualization as C-L I or II and “poor” visualization as C-L III or IV. We compared glottic exposure between direct and video laryngoscopy, determining the proportion of poor direct visualizations improved to good visualization with video laryngoscopy. We also determined the proportion of good direct visualizations worsened to poor visualization by video laryngoscopy.

Results

We report data on 198 patients, including 146 (74%) medical, 51 (26%) trauma, and 1 (0.51%) unknown indications. All were tracheally intubated by emergency physicians. Postgraduate year 3 or 4 residents performed 102 (52.3%) of the laryngoscopies, postgraduate year 2 residents performed 60 (30.8%), interns performed 20 (10.3%), attending physicians performed 9 (4.6%), and operator experience and specialty were not reported in 4. Overall, good visualization (C-L grade I or II) was attained in 158 direct (80%) versus 185 video laryngoscopies (93%; McNemar's P<.0001). Of the 40 patients with poor glottic exposure on direct laryngoscopy, video laryngoscopy improved the view in 31 (78%; 95% confidence interval 62% to 89%). Of the 158 patients with good glottic view on direct laryngoscopy, video laryngoscopy worsened the view in 4 (3%; 95% confidence interval 0.7% to 6%).

Conclusion

Video laryngoscopy affords more grade I and II views than direct laryngoscopy and improves glottic exposure in most patients with poor direct glottic visualization. In a small proportion of cases, glottic exposure is worse with video than direct laryngoscopy.

Le texte complet de cet article est disponible en PDF.

Plan


 Supervising editor: Henry E. Wang, MD, MS
 Author contributions: CAB served as principal investigator and developed the study concept. CAB and AEB maintained data integrity and site compliance. CAB, DJP, and RMW wrote the article. All authors edited the article. AEB served as primary site investigator at our second center and contributed to study design and article development. DJP performed all database retrievals and performed all statistical analyses. EGL acted as coinvestigator at our second center and contributed to study implementation. RMW created the overall database design and application, as well as the Web-based data entry form, and advised on statistical analyses and reporting of results. CAB takes responsibility for the paper as a whole.
 Funding and support: By Annals policy, all authors are required to disclose any and all commercial, financial, and other relationships in any way related to the subject of this article that might create any potential conflict of interest. See the Manuscript Submission Agreement in this issue for examples of specific conflicts covered by this statement. This study was supported by a research grant from Karl Storz Endoscopy of America (KSEA) for execution of the trial. At each site, KSEA provided 2 video Macintosh laryngoscope blades (sizes 3 and 4), a DCI II video cartridge with cables, and a telepak video display unit.
 Publication date: Available online March 3, 2010.
 Reprints not available from the authors.
 Please see page 84 for the Editor's Capsule Summary of this article.


© 2009  American College of Emergency Physicians. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 56 - N° 2

P. 83-88 - août 2010 Retour au numéro
Article précédent Article précédent
  • Electronic Health Records: Promises and Realities : A 3-Part Series Part I: The Digital Sea Change, Ready or Not
  • William B. Millard
| Article suivant Article suivant
  • Endotracheal Tube Intracuff Pressure During Helicopter Transport
  • Marco Bassi, Mathias Zuercher, Jean-Jacques Erne, Wolfgang Ummenhofer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.