To determine the relative yields of Holter monitoring (HM), memory loop recording (MLR), and autotriggered MLR (AT-MLR), we retrospectively interrogated the very large database of Lifewatch (a Card Guard company and a commercial monitoring company) and compared the results obtained by each method. From among a total database of 100,000 patients, records of 1,800 patients from 2003 were randomly selected and examined, 600 from each of the 3 different monitoring groups. Each session of MLR and AT-MLR was applied for 30 days. For each patient we determined the symptomatic and asymptomatic events that were documented, including those that met predefined immediate physician notification criteria and the time to first notification event. The groups were identical in age and symptoms that necessitated monitoring; fewer women had HM. Information on the type of underlying structural heart disease, if present, and medications taken, if any, was not available to us in this database. The AT-MLR approach provided a higher yield of diagnostic events (e.g., 37, 108, and 216 total patients who had events; 37, 212, and 524 total events; and 6.2%, 17%, and 36% with a diagnostic yield for HM, MLR, and AT-MLR, respectively) and an earlier diagnosis. AT-MLR was also the most effective technique for capturing asymptomatic significant events, such as atrial fibrillation (52 with AT-MLR vs 1 for standard MLR). AT-MLR detected more than half as many asymptomatic episodes of atrial fibrillation (n = 52) as the total number of symptomatic episodes detected by patient activated recording (n = 94), thus confirming the common presence of asymptomatic atrial fibrillation. AT-MLR provided electrocardiographic documentation of tachyarrhythmias (n = 392) more often than MLR (n = 47) or HM (n = 44) and bradyarrhythmias/pauses/atrioventricular block (n = 38) more often than MLR (n = 13) or HM (n = 18). Thus, MLR and AT-MLR provide a diagnosis more often than does HM, thus confirming the benefit of prolonged monitoring. Further, the higher yield of AT-MLR versus MLR demonstrates the significantly enhanced benefit of autotriggered programmable recording.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 9

P. 1055-1059 - mai 2005 Retour au numéro
Article précédent Article précédent
  • Comparison of the Relation of Triglyceride-Rich Lipoproteins and Muscular Artery Compliance in Healthy Women Versus Healthy Men
  • Ngoc-Anh Le, W. Virgil Brown, Warren W. Davis, David M. Herrington, Lori Mosca, Shunichi Homma, Barry Eggleston, Howard J. Willens, Jeffrey K. Raines
| Article suivant Article suivant
  • Long-Term Effects of Stress Reduction on Mortality in Persons ≥55 Years of Age With Systemic Hypertension
  • Robert H. Schneider, Charles N. Alexander, Frank Staggers, Maxwell Rainforth, John W. Salerno, Arthur Hartz, Stephen Arndt, Vernon A. Barnes, Sanford I. Nidich

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.