S'abonner

Coronary venous imaging with electron beam computed tomographic angiography: Three-dimensional mapping and relationship with coronary arteries - 21/08/11

Doi : 10.1016/j.ahj.2004.09.050 
Songshou Mao, MD, Jerold S. Shinbane, MD, Marc J. Girsky, MD, Janis Child, RT, Sivi Carson, RT, Ronald J. Oudiz, MD, Matthew J. Budoff, MD
Division of Cardiology, Harbor-UCLA Research and Education Institute, Torrance, Calif 

Reprint requests: Matthew J. Budoff, MD, Harbor-UCLA Medical Center, 1124 W Carson Street, Building RB-2, Torrance, CA 90502-2064.

Résumé

Background

The coronary venous system can provide vascular access for diagnostic and therapeutic procedures. Visualization of the coronary veins and their relationship to other cardiac structures may play an important role in facilitating these procedures. We sought to assess the ability of electron beam computed tomographic angiography (EBCTA) to characterize 3-dimensional (3-D) coronary venous anatomy.

Methods

Two hundred thirty-one consecutive EBCTA coronary studies were analyzed. The coronary venous system was mapped and analyzed using 2- and 3-D images with definition of diameter and angulations of branch vessels and distance from CS os.

Results

The coronary sinus (CS), great cardiac, middle cardiac, left ventricular (LV) anterior interventricular, LV marginal, LV posterior, left atrial, and right atrial veins were visualized in 100%, 100%, 100%, 100%, 78%, 81%, 6%, and 8% of the studies, respectively, with definition of diameter and angulations of branch vessels and distance from CS os. There was a significant linear correlation between CS diameter and right atrial end systolic volume (R = 0.244, n = 81, P < .05). No significant correlation existed between CS os diameter and other cardiac size or function parameters. The 3-D spatial arrangements between the coronary veins and the coronary arteries in relation to the epicardium were able to be defined, on the basis of the vessel closer to the epicardium in overlapping segments.

Conclusions

EBCTA can provide 3-D visualization of most components of the coronary venous system and definition of the spatial relationships with coronary arteries. EBCTA may potentially serve as a useful noninvasive tool for coronary venous imaging for procedures involving coronary veins, such as resynchronization therapy.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding was provided in part by a grant from Guidant Corporation.


© 2005  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 150 - N° 2

P. 315-322 - août 2005 Retour au numéro
Article précédent Article précédent
  • Can we reliably predict long-term mortality after exercise testing? An external validation
  • Barbara Hesse, Anthony Morise, Claire E. Pothier, Eugene H. Blackstone, Michael S. Lauer
| Article suivant Article suivant
  • Resource use, costs, and quality of life among patients in the multinational Valsartan in Acute Myocardial Infarction Trial (VALIANT)
  • Shelby D. Reed, Jasmina I. Radeva, Kevin P. Weinfurt, John J.V. McMurray, Marc A. Pfeffer, Eric J. Velazquez, Jennifer S. Allsbrook, Leah E. Masselink, Mary Ann Sellers, Robert M. Califf, Kevin A. Schulman, for the VALIANT Investigators

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.