Morphometric Analysis of Particulate Debris Extracted by Four Different Embolic Protection Devices from Coronary Arteries, Aortocoronary Saphenous Vein Conduits, and Carotid Arteries - 21/08/11

Doi : 10.1016/j.amjcard.2005.02.006 
Vu-Hung Quan, MD a, Rany Huynh, BS c, Philip A. Seifert, MS b, Arun Kuchela, MD a, Wai-Hong Chen, MBBS e, Gabor Sütsch, MD d, Andrew C. Eisenhauer, MD a, Campbell Rogers, MD a, b,
a Cardiovascular Division (Cardiac Catheterization Laboratory), Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts 
b Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts 
c Medtronic, Inc., Danvers, Massachusetts 
d Division of Cardiology, Department of Medicine, University Hospital Zurich, Zurich, Switzerland 
e Division of Cardiology, Department of Medicine, Queen Mary Hospital, Hong Kong, People’s Republic of China. 

Address for reprints: Campbell Rogers, MD, Cardiovascular Division, Brigham and Women’s Hospital, 75 Francis Street, Boston, Massachusetts 02115.

Résumé

Different embolic protection devices have been introduced for endovascular interventions: filters or balloon occlusion and aspiration systems. Despite widening use in a variety of vascular beds and clinical syndromes, little is known about the particulate burden liberated from different vascular beds and caught by different protection devices. We performed histologic and morphometric analyses of particulate debris captured during stenting of degenerated saphenous vein bypass grafts and native coronary arteries during acute myocardial infarction or during elective intervention and carotid arteries to assess the relative performance of different protection devices. We analyzed 232 interventions (90 saphenous vein bypass grafts, 77 native coronary arteries, and 65 carotid arteries) with 4 different devices (65 FilterWires, 99 Interceptors, 41 GuardWires, and 27 Proxis catheters) using the RapidVue particle analyzer. No difference in embolic volume retrieved was demonstrated between devices in saphenous vein bypass grafts and carotid interventions. A smaller volume of particulate debris was retrieved by the GuardWire compared with the FilterWire and the Proxis catheter in native coronary artery interventions. The Interceptor and the GuardWire captured more smaller particles than did the FilterWire or Proxis catheter. During saphenous vein bypass graft or carotid intervention, different embolic protection strategies were performed similarly. In native coronary artery stenting, however, proximal embolic protection retrieved larger amounts of debris than did distal filters or occlusion devices. These data may allow greater tailoring of embolic protection device development and application in specific anatomic locales.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 12

P. 1415-1419 - juin 2005 Retour au numéro
Article précédent Article précédent
  • Comparison of Effectiveness of Sirolimus-Eluting Stents Versus Bare Metal Stents for Percutaneous Coronary Intervention in Patients at High Risk for Coronary Restenosis or Clinical Adverse Events
  • Antonio Marzocchi, Giancarlo Piovaccari, Antonio Manari, Enrico Aurier, Alberto Benassi, Francesco Saia, Gianni Casella, Elisabetta Varani, Andrea Santarelli, Paolo Guastaroba, Roberto Grilli, Aleardo Maresta
| Article suivant Article suivant
  • Family History, Plasma Homocysteine, and Age at Onset of Symptoms of Myocardial Ischemia in Patients With Different Methylenetetrahydrofolate Reductase Genotypes
  • Aviv Mager, Nira Koren-Morag, Mordechai Shohat, Daniella Harell, Alexander Battler

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.