S'abonner

“Full metal jacket” (stented length ?64 mm) using drug-eluting stents for de novo coronary artery lesions - 21/08/11

Doi : 10.1016/j.ahj.2005.01.050 
Jiro Aoki, MD, Andrew T.L. Ong, MBBS, FRACP, Gaston A. Rodriguez Granillo, MD, Eugène P. McFadden, MD, FRCPI, Carlos A.G. van Mieghem, MD, Marco Valgimigli, MD, Keiichi Tsuchida, MD, Georgios Sianos, MD, PhD, Evelyn Regar, MD, PhD, Peter P.T. de Jaegere, MD, PhD, Willem J. van der Giessen, MD, PhD, Pim J. de Feyter, MD, PhD, Ron T. van Domburg, PhD, Patrick W. Serruys, MD, PhD
Erasmus Medical Center, Rotterdam, Thoraxcenter, The Netherlands 

Reprint requests: Patrick W. Serruys, MD, PhD, Thoraxcenter, Bd406, Erasmus MC, Dr Molewaterplein 40, 3015-GD Rotterdam, The Netherlands.

Résumé

Background

Stented segment length was a predictive factor for restenosis in the bare metal stent era. The objective of the study was to evaluate the medium-term clinical outcome and the potential for adverse effects when very long segments (ie, ≥64 mm of stented length) are treated by drug-eluting stent (DES) implantation, an approach colloquially referred to as a “full metal jacket.”

Methods

Since April 2002, we have used DES as the default stent for all percutaneous coronary interventions. From our prospective institutional database we identified 122 consecutive patients, with de novo coronary lesions, in whom a coronary artery was treated with at least 64 mm of overlapping DES: 81 patients were treated with sirolimus-eluting stents and 41 with paclitaxel-eluting stents.

Results

The mean number of stents per lesion was 3.3 ± 1.1, and the median stented length was 79 mm (range 64-168 mm). Periprocedural Q-wave myocardial infarction (MI) occurred in 2 patients (1.6%) and subacute stent thrombosis in 1 patient (0.8%). During 1-year follow-up, 5 patients (4.1%), including 3 patients treated for acute MI with cardiogenic shock, died and 10 patients (8.2%) had nonfatal MI (creatine kinase–MB >3 times). The 1-year target vessel revascularization rate was 7.5% and the overall incidence of major adverse cardiac events was 18%. Outcomes in sirolimus-eluting stents and paclitaxel-eluting stents groups did not differ statistically.

Conclusions

The use of DES for the treatment of diffuse lesions was associated with a low rate of repeat revascularization, irrespective of stent type. No safety concerns were raised at medium-term follow-up.

Le texte complet de cet article est disponible en PDF.

Plan


 No author has any conflict of interest. All authors have read and approved submission of the manuscript and the manuscript has not been published and is not being considered for publication elsewhere in whole or part in any language except as an abstract.


© 2005  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 150 - N° 5

P. 994-999 - novembre 2005 Retour au numéro
Article précédent Article précédent
  • A randomized trial in patients undergoing percutaneous coronary angioplasty: Roxithromycin does not reduce clinical restenosis but angioplasty increases antibody concentrations against Chlamydia pneumoniae
  • Jan Kaehler, Antje Haar, Klaus-Peter Schaps, Andreas Gaede, Marion Carstensen, Ilka Schalwat, Ralf Koester, Rainer Laufs, Thomas Meinertz, Wolfram Terres
| Article suivant Article suivant
  • Admission glucose concentrations independently predict early and late mortality in patients with acute myocardial infarction treated by primary or rescue percutaneous coronary intervention
  • Edwin Straumann, David J. Kurz, Jörg Muntwyler, Irene Stettler, Marcel Furrer, Barbara Naegeli, Jürgen Frielingsdorf, Ernst Schuiki, Raymond Mury, Osmund Bertel, Giatgen A. Spinas

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.