S'abonner

Corneal Changes and Wavefront Analysis after Orthokeratology Fitting Test - 21/08/11

Doi : 10.1016/j.ajo.2007.05.030 
Iane Gonçalves Stillitano , Maria Regina Chalita, Paulo Schor, Eduardo Maidana, Marcelo Mastromonico Lui, Cesar Lipener, Ana Luisa Hofling-Lima
Contact Lens & Refractive Surgery Sectors, Department of Ophthalmology, Federal University of São Paulo/Paulista School of Medicine UNIFESP/EPM, São Paulo, Brazil. 

Inquiries to Iane Gonçalves Stillitano, Rua Botucatu, 822, São Paulo-SP, Brazil 04023062

Résumé

Purpose

To evaluate corneal changes and ocular aberrations during an orthokeratology test.

Design

A prospective, nonrandomized cohort study.

Methods

Fourteen myopic patients (26 eyes) underwent an orthokeratology fitting test with the BE contact lens (Ultravision Pty, Ltd, Brisbane, Australia). Best spectacle-corrected visual acuity (BSCVA), uncorrected (Ultravision Pty, Ltd, Brisbane, Australia) visual acuity (UCVA), subjective cycloplegic refraction, biomicroscopy, corneal topography, optical pachymetry, and aberrometry were performed at baseline and one and eight nights orthokeratology. The short-term effect of orthokeratology using corneal topography, tomography, and ocular aberrations was evaluated.

Results

The mean spherical equivalent changed from −2.24 ± 0.98 diopters (D) at baseline to 0.15 ± 0.76 D after the eight nights of lens wear (P = .001). All patients had an UCVA of 20/30, 69.2% with 20/20. Changes in central corneal pachymetry were not observed. There was a statistically significant increase in the temporal corneal thickness from night one, without any difference between nights one and eight (P > .001). A significant increase of higher-order root mean square values was observed from baseline (0.42 ± 0.16 μm), night one (0.81 ± 0.24 μm), and night eight (1.04 ± 0.24 μm). Increases in coma (Z7+Z8) and spherical aberration (Z12) were observed. Positive horizontal (Z8) coma increased in right eyes, and negative horizontal (Z8) coma increased in left eyes (P < .001).

Conclusions

Myopia reduction resulting from rapid central corneal flattening and improvement of UCVA occurred after orthokeratology. Higher-order aberrations (HOAs), particularly spherical aberration and coma, increased significantly during the orthokeratology test. An increase of temporal pachymetry and differences in coma direction induced between the eyes may be related to the subclinical lens decentration temporally.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 144 - N° 3

P. 378-386 - septembre 2007 Retour au numéro
Article précédent Article précédent
  • Long-term Safety and Functional Outcome of Combined Pars Plana Vitrectomy and Scleral-Fixated Sutured Posterior Chamber Lens Implantation
  • Gundula Bading, Jost Hillenkamp, Helmut G. Sachs, Veit-Peter Gabel, Carsten Framme
| Article suivant Article suivant
  • Combined Intacs and Posterior Chamber Toric Implantable Collamer Lens Implantation for Keratoconic Patients with Extreme Myopia
  • Efekan Coskunseven, Methiye Onder, George D. Kymionis, Vasilios F. Diakonis, Ebru Arslan, Nikolaos Tsiklis, Dimitrios I. Bouzoukis, Ioannis Pallikaris

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.