Gauze pledgetting versus endoscopic-guided aerosolized spray for nasal anesthesia before transnasal EGD: a prospective, randomized study - 22/08/11

Doi : 10.1016/j.gie.2009.06.016 
Chi-Tan Hu, MD, PhD ⁎
Current affiliation: Division of Gastroenterology and Research Centre for Hepatology, Department of Internal Medicine, Buddhist Tzu Chi General Hospital and Graduate Institute of Clinical Medicine, School of Medicine, Tzu Chi University, Hualien, Taiwan 

Reprint requests: Chi-Tan Hu, MD, PhD, Division of Gastroenterology, Department of Internal Medicine, Buddhist Tzu Chi Hospital and Tzu Chi University, No 707, Section 3, Chung Yang Road, Hualien (970), Taiwan.

Hualien, Taiwan

Abstract

Background

Methods and efficacy of nasal anesthesia before ultrathin transnasal EGD (UT-EGD) are crucial for patient tolerance.

Objective

To compare patient tolerance, safety, and adverse events between cotton-tipped applicator primed gauze pledgetting (CTGP) and endoscopic-guided aerosolized spray (EGAS) methods of nasal anesthesia.

Design

We performed a prospective, randomized-controlled trial to compare procedural discomforts, optical quality, total procedure time, and adverse events between the CTGP and EGAS methods.

Setting

A large, tertiary referral hospital in Taiwan.

Patients

A total of 240 consecutive patients with epigastric discomfort were included in the study.

Intervention

The author performed all standardized nasal anesthesia and UT-EGD using a 5.9-mm diameter transnasal endoscope.

Main Outcome Measurements

Technical success, patient tolerability profiles, optical quality, total procedure time, and adverse events.

Results

There was no statistical difference in insertion failure rates between the 2 methods (CTGP 0% vs EGAS 5%, P = .07). When compared with the EGAS method, CTGP reduced pain during insertions through the inferior nasal meatus (3.4 ± 0.5 vs 3.2 ± 0.4, P = .006), middle nasal meatus (4.0 ± 0.7 vs 3.4 ± 0.5, P = .002), and upper esophageal sphincter (2.9 ± 0.7 vs 2.6 ± 0.8, P = .005). CTGP elicited less unpleasant taste, fewer gagging episodes, and less throat pain after examination. Both methods had similar safe hemodynamic profiles, low epistaxis rates (0% vs 2%, P = .46), and comparable visual capacity and procedure time. Although similar proportions of patients in both groups would like to receive the same procedure the next time, CTGP had a higher overall tolerance.

Conclusion

Compared with the EGAS method, CTGP achieved a better tolerability profile and elicited less bad taste, fewer gagging episodes, and less throat pain after UT-EGD in Taiwanese patients.

Le texte complet de cet article est disponible en PDF.

Abbreviations : BMI, CTGP, CTNA, EGAS, INM, INT, MNM, MNT, P-EGD, UT-EGD, VAS


Plan


 DISCLOSURE: The author disclosed financial relationships relevant to this publication: Fujinon Corporation, Tokyo, Japan supplied the Fujinon super-slim transnasal endoscope EG-530N affiliated with Fujinon super-CCD, which were used for ultrathin endoscopic procedures in this study. This author was supported by grant TCCSP95-09 from Buddhist Tzu Chi Intramural Research Plan.
 If you would like to chat with an author of this article, you may contact Dr. Hu at [email protected] or [email protected].


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 71 - N° 1

P. 11-20 - janvier 2010 Retour au numéro
Article précédent Article précédent
  • A short note from the Editor-in-Chief: the next 5 years of GIE
  • Glenn Eisen
| Article suivant Article suivant
  • Age- and sex-specific yield of Barrett’s esophagus by endoscopy indication
  • Joel H. Rubenstein, Nora Mattek, Glenn Eisen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.