S'abonner

Effectiveness of asynchronous tele-endoscopy - 22/08/11

Doi : 10.1016/j.gie.2009.10.020 
Anushiya Ganeshalingam, BASc, MHSc, Sean Pritchett, MD, FRCPC, Tony Tam, MD, BASc, MHSc, PEng, Joseph A. Cafazzo, PhD, PEng, Peter G. Rossos, MD, MBA, FRCP(C), FACP
Division of Gastroenterology, (P.G.R.), Health Policy, Management and Evaluation and the Institute of Biomaterials and Biomedical Engineering, Faculty of Medicine, (J.A.C.), Faculty of Medicine (A.G., S.P., T.T.), University of Toronto, Toronto, Ontario, Canada, Centre for Global eHealth Innovation, University Health Network (P.G.R., J.A.C.), Toronto, Ontario, Canada 

Reprint requests: Peter G. Rossos, MD, Toronto General Hospital, 200 Elizabeth Street, Suite 9EN-215, Toronto, ON M5G 2C4, Canada.

Toronto, Ontario, Canada

Abstract

Background

Asynchronous tele-endoscopy can improve access and quality of patient care. This is the first published evaluation of the diagnostic accuracy of highly compressed digital video in GI endoscopy.

Objective

To determine whether asynchronous tele-endoscopy using highly compressed video can accurately document and diagnose lesions in the upper GI tract.

Design

Local endoscopists performed 50 elective upper GI endoscopies. A high-quality DV compressed video (25 megabits per second [Mbps], 720 × 480 pixels) and highly compressed MPEG-1 video (2.0 Mbps, 352 × 240 pixels) were simultaneously captured. Five endoscopists asynchronously reviewed 20 compressed digital videos (100 case reviews) for endoscopic diagnoses. In addition, demonstration technique and image quality were rated on a Likert scale. Concordance between local and asynchronous endoscopists for major and minor endoscopic findings was evaluated. An independent panel classified discrepancies as caused by image quality, endoscopic technique, or interobserver variability through comparison of the 2 forms of digital video.

Results

Although asynchronous endoscopists rated the image quality of highly compressed video as diagnostic in 85% of cases, only 18% of studies yielded the same clinical diagnoses. There was high discordance for both major (kappa = 0.38, 95% CI, 0.19-0.57) and minor findings (kappa = −0.29, 95% CI, −0.43 to −0.15). Interobserver reporting was responsible for 90% of variability in contrast to only 4.9% for poor image quality.

Conclusions

The findings suggest that the diagnostic accuracy of low-bandwidth, low-resolution, highly compressed video is well tolerated and comparable to the current standard. Interobserver reporting variability accounted for most of the poor correlation. Improved synoptic documentation is required for effective communication among endoscopists.

Le texte complet de cet article est disponible en PDF.

Abbreviations : LCD, mbps, MST, UGI


Plan


 DISCLOSURE: The study was funded through the Centre for Global e-Health Innovation (www.ehealthinnovation.org/) as part of an electronic health record development and evaluation initiative. All authors disclosed no financial relationships relevant to this publication.


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 71 - N° 3

P. 461 - mars 2010 Retour au numéro
Article précédent Article précédent
  • A new metal stent with a controlled-release system for palliation of malignant dysphagia: a prospective, multicenter study
  • Petra G.A. van Boeckel, Alessandro Repici, Frank P. Vleggaar, Biagio Solito, Giacomo Rando, Claudio Cortelezzi, Mauro Rossi, Nico Pagano, Alberto Malesci, Peter D. Siersema
| Article suivant Article suivant
  • Endoscopic removal of dysfunctioning bands or rings after restrictive bariatric procedures
  • Daniel Blero, Pierre Eisendrath, Alain Vandermeeren, Jean Closset, Abdel Mehdi, Olivier Le Moine, Jacques Devière

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.