S'abonner

Prospective randomized trial comparing EUS and EGD for transmural drainage of pancreatic pseudocysts (with videos) - 23/08/11

Doi : 10.1016/j.gie.2008.04.028 
Shyam Varadarajulu, MD , John D. Christein, MD, Ashutosh Tamhane, MD, MSPH, Ernesto R. Drelichman, MD, C. Mel Wilcox, MD, MSPH
Current affiliations: Division of Gastroenterology-Hepatology (S.V., A.T., C.M.W.), Department of Surgery (J.D.C., E.R.D.), University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA 

Reprint requests: Shyam Varadarajulu, MD, Division of Gastroenterology-Hepatology, University of Alabama at Birmingham Medical Ctr, 410 LHRB, 1530 3rd Ave S Birmingham, AL 35294.

Birmingham, Alabama, USA

Abstract

Background

Although prior studies evaluated the role of EUS and EGD for drainage of pancreatic pseudocysts, there are no randomized trials that compared the technical outcomes between both modalities.

Objective

To compare the rate of technical success between EUS and EGD for transmural drainage of pancreatic pseudocysts.

Study design

A prospective randomized trial.

Setting

A tertiary-referral center.

Patients

Those with a history of pancreatitis and symptomatic pancreatic pseudocysts that measured greater than 4 cm in size who were referred for endoscopic transmural drainage. Patients with pancreatic abscess or necrosis were excluded.

Main Outcome Measurements

Technical success was defined as the ability to access and drain a pseudocyst by placement of transmural stents. Complications were assessed at 24 hours and at day 30. Treatment success was defined as the complete resolution or decrease in size of the pseudocyst to ≤2 cm on CT in association with clinical resolution of symptoms at 6 weeks of follow-up.

Results

Thirty patients were randomized to undergo pseudocyst drainage by EUS (n = 15) or EGD (n = 15) over a 6-month period. Of the 15 patients randomized to EUS, drainage was not undertaken in one, because an alternative diagnosis of biliary cystadenoma was established at EUS and was excluded (after randomization) from analysis. The mean age of the patients was 47 years; 62% were men (18/29). Except for their sex, there was no difference in patient or clinical characteristics between the 2 cohorts. Although all the patients (n = 14) randomized to an EUS underwent successful drainage (100%), the procedure was technically successful in only 5 of 15 patients (33%) randomized to an EGD (P < .001). All 10 patients who failed drainage by EGD underwent successful drainage of the pseudocyst on a crossover to EUS. There was no significant difference in the rates of treatment success between EUS and EGD after stenting, either by intention-to-treat (ITT) analysis (100% vs 87%; P = .48) or as-treated analysis (95.8% vs 80%; P = .32). Major procedure-related bleeding was encountered in 2 patients in whom drainage by EGD was attempted; one resulted in death and the other necessitated a blood transfusion. No significant difference was observed between EUS and EGD with regard to complications either by ITT (0% vs 13%; P = .48) or as-treated analyses (4% vs 20%; P = .32). Technical success was significantly greater for EUS than EGD, even after adjusting for luminal compression and sex (adjusted exact odds ratio 39.4; P = .001).

Limitation

Short duration of follow-up.

Conclusions

When available, EUS should be considered as the first-line treatment modality for endoscopic drainage of pancreatic pseudocysts given its high technical success rate.

Le texte complet de cet article est disponible en PDF.

Abbreviations : DPEJ, ITT, OR, PFC, UAB


Plan


 See CME section; p. 1147.


© 2008  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 68 - N° 6

P. 1102-1111 - décembre 2008 Retour au numéro
Article précédent Article précédent
  • Prospective evaluation of adverse reactions to iodine-containing contrast media after ERCP
  • Peter V. Draganov, Chris E. Forsmark
| Article suivant Article suivant
  • Clinical evaluation of a newly developed single-balloon enteroscope
  • Takuji Kawamura, Kenjiro Yasuda, Kiyohito Tanaka, Koji Uno, Moose Ueda, Kasumi Sanada, Masatsugu Nakajima

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.