S'abonner

Newly designed stent for endoscopic bilateral stent-in-stent placement of metallic stents in patients with malignant hilar biliary strictures: multicenter prospective feasibility study (with videos) - 23/08/11

Doi : 10.1016/j.gie.2008.12.250 
Do Hyun Park, MD, PhD , Sang Soo Lee, MD, PhD , Jong Ho Moon, MD, PhD , Hyun Jong Choi, MD, Sang-Woo Cha, MD, PhD, Jong Hyeok Kim, MD, PhD, Dong-Wan Seo, MD, PhD, Sung-Koo Lee, MD, PhD, Sang-Heum Park, MD, PhD, Moon-Sung Lee, MD, PhD, Sun-Joo Kim, MD, PhD, Myung-Hwan Kim, MD, PhD
Current affiliations: Department of Internal Medicine (D.H.P., S.S.L., D.-W.S., S.-K.L., M.-H.K.), University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea, Department of Internal Medicine (J.H.M., H.J.C., M.-S.L.), Soon Chun Hyang University School of Medicine, Bucheon, South Korea, Department of Internal Medicine (S.-W.C.), Eulji University College of Medicine, Eulji University Hospital, Daejeon, South Korea, Department of Internal Medicine (J.H.K.), Hallym University Sacred Heart Hospital, Anyang, South Korea, Department of Internal Medicine (S.-H.P., S.-J.K.), Soon Chun Hyang University Cheonan Hospital, Cheonan, South Korea 

Reprint requests: Jong Ho Moon, MD, PhD, Department of Internal Medicine, Soon Chun Hyang University School of Medicine, Digestive Disease Center, Soon Chun Hyang University Bucheon Hospital, 1174 Jung-Dong, Wonmi-Ku, Bucheon 420-767, Korea.

Seoul, Bucheon, Korea

Abstract

Background

Endoscopic management of malignant hilar biliary strictures is difficult even for an experienced endoscopist. Moreover, endoscopic placement of bilateral metal stents is considered very difficult and complicated.

Objective

We explored the feasibility and efficacy of the placement of a newly designed metal stent for an endoscopic bilateral stent-in-stent procedure for the management of malignant hilar biliary strictures.

Design

Multicenter prospective feasibility study.

Setting

Five academic tertiary referral centers.

Patients

Thirty-five patients with malignant hilar biliary strictures of Bismuth type II or higher were enrolled.

Interventions

Bilateral stent placement by an endoscopic stent-in-stent procedure.

Main Outcome Measurements

Technical success, functional success, early and late complications, stent patency.

Results

The overall technical success rate of the newly designed metal stent was 94.3% (33/35). The success rate of the stent-in-stent procedure in a single session was 82% (27/33) per protocol and 77% (27/35) as intent to treat. In cases in which the initial stent-in-stent procedure failed, patients underwent the endoscopic stent-in-stent procedure for contralateral stent placement at 2 days (6%, 2/33) or 4 days (12%, 4/33) after the initial stent placement. There was no percutaneous insertion of a contralateral stent in these patients. There was no stent-related early or late complication in any enrolled patient. Functional success was 100% (33/33). Reintervention because of stent malfunction was 6% (2/33). These 2 patients showed sludge formation in the stent. During follow-up, there was no stent tumor ingrowth or overgrowth in the placed stent in any enrolled patient. According to the Kaplan-Meier analysis, median survival and stent patency were 180 days and 150 days, respectively.

Limitations

An uncontrolled feasibility study with a small patient population and a limited follow-up period.

Conclusion

The newly designed metal stent for the endoscopic bilateral stent-in-stent procedure may be feasible and effective for malignant hilar biliary strictures.

Le texte complet de cet article est disponible en PDF.

Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you want to chat with an author of this article, you may contact him at jhmoon@schbc.ac.kr.


© 2009  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 69 - N° 7

P. 1357-1360 - juin 2009 Retour au numéro
Article précédent Article précédent
  • The case of unsedated screening colonoscopy in the United States
  • Felix W. Leung
| Article suivant Article suivant
  • “Cross-wired” biliary metal stents for malignant hilar strictures: a new window of opportunity?
  • Michel Kahaleh

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.