S'abonner

Evaluation of a manually driven, multitasking platform for complex endoluminal and natural orifice transluminal endoscopic surgery applications (with video) - 23/08/11

Doi : 10.1016/j.gie.2008.11.007 
Christopher C. Thompson, MD, MSc, FASGE, FACG , Marvin Ryou, MD, Nathaniel J. Soper, MD, Eric S. Hungess, MD, Richard I. Rothstein, MD, Lee L. Swanstrom, MD
Current affiliations: Division of Gastroenterology (C.C.T., M.R.), Brigham & Women’s Hospital, Harvard Medical School, Boston, Massachusetts, Department of Surgery (N.J.S., E.S.H.), Northwestern University Feinberg School of Medicine, Chicago, Illinois, Department of Gastroenterology and Hepatology (R.I.R.), Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire, Department of Surgery (L.L.S.), Legacy Health System, Portland, Oregon, USA 

Reprint requests: Christopher C. Thompson, MD, Division of Gastroenterology, Brigham & Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115.

Boston, Massachusetts, Chicago, Illinois, Lebanon, New Hampshire, Portland, Oregon, USA

Abstract

Background

The Direct Drive Endoscopic System (DDES) is a multitasking platform developed to overcome the limitations of the currently available rigid and flexible endoscopic systems in application to natural orifice transluminal endoscopic surgery (NOTES), single-port laparoscopy, and advanced endoluminal procedures. The system consists of a 3-channel, steerable guide sheath accepting a 6-mm endoscope and two 4-mm articulating instruments. The system’s overall design enables the interventionalist to operate instruments bimanually from a stable platform, conveying a laparoscopic paradigm to the functional working space at the distal end of the flexible guide sheath.

Objective

To assess the basic functionality of the DDES device in a series of defined exercises by using ex vivo porcine stomachs and 1 in vivo animal model.

Design

Ex vivo calibration and training exercises, including EMR, full-thickness suturing, and knot tying.

Setting

Animal laboratory.

Interventions

EMR, full-thickness suturing, and knot tying.

Main Outcome Measurements

Successful completion of specified tasks.

Results

Independent instrument movement with a wide range of motion allowed the interventionalist to perform several complex tasks efficiently. The DDES was able to (1) grasp tissue and hold it under tension, (2) cut through layers of porcine stomach in a controlled fashion, (3) suture, and (4) tie knots.

Limitation

Ex vivo study.

Conclusions

This novel multitasking platform demonstrated surgical functionality including triangulation, cutting, grasping, suturing, and knot tying. Preliminary results suggest that the DDES can perform complex endosurgical tasks that have traditionally been challenging or impossible with the standard endoscopic paradigm, and may enable NOTES, single-port laparoscopy, and complex endoluminal procedures.

Le texte complet de cet article est disponible en PDF.

Abbreviations : DDES, NOTES


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: C. C. Thompson, N. J. Soper, R. I. Rothstein, L. L. Swanstrom: Consultants for Boston Scientific Corporation. C. C. Thompson and R. I. Rothstein: On the patent for the DDES. All other authors disclosed no financial relationships relevant to this publication.


© 2009  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 70 - N° 1

P. 121-125 - juillet 2009 Retour au numéro
Article précédent Article précédent
  • Randomized controlled study of EMR versus endoscopic submucosal dissection with a water-jet hybrid-knife of esophageal lesions in a porcine model
  • Horst Neuhaus, Katja Wirths, Martin Schenk, Markus Dominik Enderle, Brigitte Schumacher
| Article suivant Article suivant
  • Feasibility study of natural orifice transluminal endoscopic surgery inguinal hernia repair
  • Danny A. Sherwinter, Jeremy G. Eckstein

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.