S'abonner

Current limitations in endoscopic CO2 insufflation for NOTES: flow and pressure study - 24/08/11

Doi : 10.1016/j.gie.2010.07.002 
Kiyokazu Nakajima, MD, PhD , Toshirou Nishida, MD, PhD, Jeffrey W. Milsom, MD, Tsuyoshi Takahashi, MD, PhD, Yoshihito Souma, MD, Yasuaki Miyazaki, MD, Hideki Iijima, MD, PhD, Masaki Mori, MD, PhD, Yuichiro Doki, MD, PhD
 Current affiliations: Departments of Surgery (K.N., T.T., Y.S., Y.M., M.M., Y.D.) and Gastroenterology and Hepatology (H.I.), Osaka University Graduate School of Medicine, Osaka, Japan, Department of Surgery (T.N.), Osaka Police Hospital, Osaka, Japan, Department of Surgery (J.W.M.), Weill Medical College of Cornell University, New York, New York, USA 

Reprint requests: Kiyokazu Nakajima, MD, PhD, Department of Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, Osaka 565-0871, Japan

Résumé

Background

Natural orifice transluminal endoscopic surgery (NOTES) requires fast and steady CO2 insufflation into the intraluminal and intra-abdominal spaces through a flexible endoscope. However, an optimal endoscopic insufflation system has yet to be determined.

Objective

To verify the performances of 2 currently available CO2 insufflators in an experimental NOTES setting: (1) an automatic pressure-regulated surgical insufflator (UHI-3) and (2) a manual endoscopic insufflator (UCR).

Design

An inanimate bench study followed by an acute animal experiment.

Setting

Osaka University and Olympus Research and Development Department.

Main Outcome Measurements

The UHI-3 or UCR was connected to an endoscope of differing length and diameter via an insufflating line of differing length and diameter. The flow rates at the tip of the endoscope (bench test), the time to establish pneumoperitoneum, and the time to re-establish pneumoperitoneum after forceful suction (porcine model) were obtained.

Results

The UHI-3 failed to feed CO2 through an insufflating channel but fed CO2 via a working channel but required a large channel (>3 mm) and a wide insufflating line (>7 mm) to accomplish an acceptable flow rate. UCR fed CO2 through the insufflating channel; however, the time taken to establish pneumoperitoneum and the time taken to re-establish pneumoperitoneum after forceful suction were longer compared with the time taken for UHI-3 insufflation via the working channel or laparoscopic cannula.

Limitations

Bench/animal study with small sample numbers; no human trial.

Conclusions

The currently available CO2 insufflators are not optimal for NOTES. Modification of an endoscopic insufflation system and/or development of a dedicated overtube with an insufflating function are therefore essential.

Le texte complet de cet article est disponible en PDF.

Abbreviations : NOTES


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: Dr. Nakajima: Research grant and honorarium for seminars, Olympus Medical Systems, and research grant from Hakko. Drs Nakajima, Nishida, Iijima, and Milson were supported by a Natural Orifice Surgery Consortium for Assessment and Research (NOSCAR) 2008 research grant. All other authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Nakajima at knakajima@gesurg.med.osaka-u.ac.jp.


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 72 - N° 5

P. 1036-1042 - novembre 2010 Retour au numéro
Article précédent Article précédent
  • Natural orifice transluminal endoscopic surgery: looking beyond the gallbladder
  • Jeffrey M. Marks
| Article suivant Article suivant
  • Continuing Medical Education Exam: November 2010
  • Raquel E. Davila, Jeffrey H. Lee, William Ross, Shou-Jiang Tang, G.S. Raju, Glenn M. Eisen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.