S'abonner

A novel endoscopic device for repeated right-side colonic access during colonoscopy (with video) - 24/08/11

Doi : 10.1016/j.gie.2009.12.059 
Arnulf Ferlitsch, MD , Gerd R. Silberhumer, MD, Wayne Noda, Tudor Birsan, MD, Devendra Desai, MD, Ajay Kumar, MD, Guduru V. Rao, MD, Aditya Khakar, MD, Nestor A. Gomez, MD, Christoph Gasche, MD
Current affiliations: Departments of Medicine 3 (A.F., C.G.), General Surgery (G.S., T.B.), Medical University of Vienna, Vienna, Austria; Minos Medical, Irvine, California (W.N., C.G.); Hinduja Hospital, Mumbai, India (D.D.); Indraprastha Apollo Hospital, New Delhi, India (A.J.); Asian Institute of Gastroenterology, Hyderabad, India (G.R.); Janaki Centre, Kohapur, India (A.K.); Kennedy Hospital, Guayaquil, Ecuador (N.G.) 

Reprint requests: Prof. Christoph Gasche, Dept. of Medicine 3, Division of Gastroenterology and Hepatology, Medical University of Vienna

Résumé

Background

Megachannel is a newly developed colonic access system allowing rapid and multiple passes of the colonoscope to the right side of the colon.

Objective

The aim of this study was to evaluate the safety and clinical feasibility of placing a 100 cm Megachannel prototype in the right side of the colon.

Setting

Six centers, international, both surgeons and gastroenterologists performing endoscopy.

Design and Intervention

Patients scheduled for colonoscopy with suspected right-side colonic polypoid lesions were included. The prototype was loaded onto a 160 cm lower GI endoscope and introduced via colonoscopic guidance.

Main Outcome Measurement

The ability to place this device in the right side of the colon.

Results

The Megachannel prototype was introduced in 41 patients (19 female, mean age 54 years) undergoing colonoscopy. The cecum was reached in 27 cases (66%) within 18 minutes (range, 3-35 minutes) and with 73 cm (range, 40-100 cm) of the device being inserted into the colon. Mild tissue bruises and mild pain were observed in 5 and 3 patients, respectively. In 14 patients, the device assisted the removal of multiple polyps (2-12) as tissue was repeatedly retrieved through the channel. The device also allowed delivery of an endoscopic US scope or suction caps to the right side of the colon.

Limitations

Prototype performance may differ from the actual product (80 cm in length, redesigned introducer plugs). Small number of patients, difficult in diverticular disease.

Conclusions

This newly developed colonic access system can be safely placed in the right side of the colon and is useful for a variety of advanced procedures that require repeated insertion of the colonoscope or delivery of bulky instruments. (Clinical trial registration number: NCT00987896.)

Le texte complet de cet article est disponible en PDF.

Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 71 - N° 6

P. 1052-1055 - mai 2010 Retour au numéro
Article précédent Article précédent
  • Carbon dioxide insufflation is useful for obtaining clear images of the bile duct during peroral cholangioscopy (with video)
  • Toru Ueki, Motowo Mizuno, Shigeru Ota, Tsuneyoshi Ogawa, Hiroshi Matsushita, Daisuke Uchida, Norifumi Numata, Asuka Ueda, Yuuki Morimoto, Yoko Kominami, Shintaro Nanba, Manabu Kurome, Hirotoki Ohe, Masahiro Nakagawa, Yasuyuki Araki
| Article suivant Article suivant
  • Endoscopic submucosal dissection by using a flexible Maryland dissector: a randomized, controlled, porcine study (with videos)
  • Daniel von Renteln, Heiko Pohl, Melina C. Vassiliou, Matthew M. Walton, Richard I. Rothstein

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.