S'abonner

Alternative for Primary Pericardial Closure: Sentry for Re-entry - 24/08/11

Doi : 10.1016/j.hlc.2004.01.008 
Nitin Ghorpade, M.Ch., David Hill, MBBS, FRACS, Morteza Mohajeri, MBBS, FRACS
Department of Cardiothoracic Surgery, The Geelong Hospital, P.O. Box 281, Geelong, Vic. 3220, Australia 

*Corresponding author. Tel.: +61-3-5226-7081; fax: +61-3-5260-3141.

Abstract

Background. Redo cardiac surgery is considered high-risk surgery as accidental injury to the aorta, the innominate vein, the ventricles and the atria is a possibility. Such accidental injury occurs when the cardiac chamber is adherent to the undersurface of the sternum. Closure of pericardium at the time of primary surgery can prevent adherence of cardiac chambers to the sternum, but may increase the risk of tamponade. This study aimed to show that covering heart with a pedicled pericardial fat pad not only serves the purpose of cover but also avoids the adverse haemodynamic effects of primary pericardial closure.

Methods. Forty patients undergoing elective cardiac surgery were randomised into two groups depending on the way pericardium was managed. Both techniques were already in routine use in our unit and in other units around the country. One method is to leave the pericardium widely open, the other is to loosely oppose the pericardial fat pad over the surface of the aorta and right ventricle. Twenty-three patients had a pedicled pericardial fat pad covering the heart: Closure Group. Seventeen patients had no pericardial fat pad cover over the heart: Open Group. A haemostasis clip was used as a radio-opaque marker over the epicardium in both groups. Post-operation heart rate, central venous pressure, pulmonary artery diastolic pressure, mean arterial pressure and cardiac index were measured and recorded 1, 3 and 8h after surgery. The distance between the haemoclip and the posterior table of the sternum was measured at 6 days and 6 months post-operation. Haemodynamic parameters and the retrosternal space depth were compared between the two groups.

Results. There were no important differences in haemodynamic parameters between the two groups. Post-operative lateral chest Roentgenograms showed that the distance between epicardial surface and the posterior table of sternum was larger in the Closure Group compared to Open Group on post-operative day 6, 17.5±1.0mm versus 13.4±1.3mm (P=0.0013) and 6 months later, 12.3±0.8mm versus 6.0±1.2mm (P<0.001). There was no mortality in either group.

Conclusion. Pedicled pericardial fat pad cover is a good alternative to primary pericardial closure as there are no adverse haemodynamic effects in early post-operative period and the long-term benefit of protection of heart at the time of re-sternotomy can be expected.

Le texte complet de cet article est disponible en PDF.

Keywords : Redo cardiac surgery, Pericardial closure, Cardiac tamponade


Plan


© 2004  Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 13 - N° 1

P. 52-55 - mars 2004 Retour au numéro
Article précédent Article précédent
  • Allograft Aortic Valve Replacement in the Adult: A Review
  • Cheng-Hon Yap, Michael Yii
| Article suivant Article suivant
  • Viable Extracardiac Total Right Heart Bypass: Technical Considerations and Mid-term Results
  • Ujjwal K Chowdhury, Shyam S Kothari, Anita Saxena, Akhil Govil, Ganapathy Subramaniam, Balram Airan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.