S'abonner

Umbilical cord pH and base excess values in relation to adverse outcome events for infants delivering at term - 25/08/11

Doi : 10.1016/j.ajog.2004.04.026 
Rahi Victory, MD, Deborah Penava, MD, Orlando da Silva, MD, Renato Natale, MD, Bryan Richardson, MD
Department of Obstetrics and Gynaecology, Paediatrics and Physiology, St. Joseph's Health Care, University of Western Ontario, London, Ontario, Canada 

Reprint requests: Bryan S. Richardson, MD, Department of Obstetrics and Gynaecology, St. Joseph's Health Care, 268 Grosvenor St, London, Ontario, Canada N6A 4V2.

Abstract

Objective

This study was undertaken to determine the relationship of umbilical cord pH and base excess (BE) values to adverse neonatal outcomes for a large tertiary hospital population delivering at term.

Study design

The perinatal/neonatal database of St. Joseph's Health Care, London, Canada, was used to obtain the umbilical cord pH and BE values, incidence of adverse neonatal outcomes, and patient demographics for all term (≥37 weeks' gestation), singleton, liveborn infants with no major anomalies delivering between November 1995 and March 2002 (n=20,456). Statistical analyses included χ2 analysis, logistic regression models to develop odds ratios and creation of receiver operating characteristic (ROC) curves with area under curve (AUC) calculations.

Results

Umbilical vein and artery pH and BE values for this tertiary care population averaged 7.33 ± 0.06 and 7.24 ± 0.07, and −4.5 ± 2.4 and −5.6 ± 3.0 mmol/L, respectively. Apgar less than 7 at 5 minutes, neonatal intensive care unit (NICU) admission, and assisted neonatal ventilation had significant inverse relationships with both umbilical artery and umbilical vein pH and BE (all P < .0001), with marginal increases in the incidences of these outcomes beginning with cord blood values close to the mean, and more substantial increases with cord values less than 1 or 2 SD below the mean, depending on the outcome studied. The ROC AUC for all these relationships were significant (P < .001) ranging from 0.76 to 0.79 when predicting Apgar less than 7 at 5 minutes to 0.68 to 0.70 when predicting NICU admission, and with cutoff cord blood values at which sensitivity and specificity were maximized again close to mean values. For each of these neonatal outcomes, the relation to cord blood values was similar with little difference in the data analysis whether using pH or BE values, and whether from the umbilical artery or vein.

Conclusion

There is a progression of risk in term infants for Apgar less than 7 at 5 minutes, NICU admission, and need for assisted ventilation with worsening acidosis at birth, which begins with cord blood values close to mean values indicating a higher threshold for associated acidemia with these outcomes than is seen for more severe neonatal outcomes.

Le texte complet de cet article est disponible en PDF.

Keywords : Umbilical cord blood, pH, Base excess, Acidosis, Neonatal morbidity


Plan


 B. Richardson is a member of the CIHR Group in Fetal and Neonatal Health and Development and is the current recipient of the Wyeth Research Chair in Women's Health for Perinatology.


© 2004  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 191 - N° 6

P. 2021-2028 - décembre 2004 Retour au numéro
Article précédent Article précédent
  • Interferon alfa treatment for pregnant women affected by essential thrombocythemia: Case reports and a review
  • Pasquale Martinelli, Vincenzo Martinelli, Annalisa Agangi, Giuseppe Maria Maruotti, Dario Paladini, Rosanna Ciancia, Bruno Rotoli
| Article suivant Article suivant
  • Combined logistic and Bayesian modeling of cesarean section risk
  • Gordon C.S. Smith, Michael Dellens, Ian R. White, Jill P. Pell

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.