Evaluation of synchronous twin pulse technique for shock wave lithotripsy: in vivo tissue effects - 26/08/11

Doi : 10.1016/S0090-4295(03)00685-X 
Khaled Z Sheir a, , David Lee b, Peter A Humphrey c, Kevin Morrissey c, Chandru P Sundaram d, Ralph V Clayman b
a Urology and Nephrology Center, Mansoura University, Mansoura, Egypt 
b Department of Urology, University of California, Irvine, Irvine, California, USA 
c Department of Pathology and Division of Urology, Washington University School of Medicine, St. Louis, Missouri, USA 
d Department of Urology, Indiana University School of Medicine, Indianapolis, Indiana, USA 

*Reprint requests: Khaled Z. Sheir, M.D., Department of Urology, Urology and Nephrology Center, Mansoura University, Elgomhoria Street, Mansoura 35516, Egypt

Abstract

Objectives

To study the in vivo tissue effects of synchronous twin pulse technology. Recently, the concept of a synchronous twin pulse technique for shock wave therapy has been introduced with the development of the Twinheads' unit.

Methods

In 10 pigs (20 kidneys), one of three sites was targeted: the renal pelvis (2 pigs), the mid-zone parenchyma (5 pigs), or the lower pole parenchyma (3 pigs). The treatment parameters were 1000 twin shock waves at 14 kV with a 90° angle between the shock wave reflectors using a rate of 60 shock waves/min in 17 kidneys and 120 shock waves/min in 3 kidneys. To study the effect of an increasing number of twin shock waves, 4 animals (8 kidneys) were used; the mid-zone parenchyma was subjected to 2000 and 3000 twin shock waves in 4 kidneys each, using a rate of 60 shock waves/min at 14 kV and a 90° angle in all of them. For comparison with the use of a single head, another 3 animals (6 kidneys) were treated with the use of the single under-table head; all of them received 2000 single shock waves at 14 kV focused on the mid zone of the kidney parenchyma. Within 1 hour of treatment, the treated kidneys were harvested, inspected, and sectioned at the focal site, as well as at 1 and 2 cm distant to the focal site.

Results

No gross lesions of the surrounding organs, subcapsular hemorrhage, or parenchymal damage were found at the outer surfaces of the kidneys undergoing twin head shock wave lithotripsy even after 3000 twin shocks. The coronal section revealed minimal gross lesions in 4 of 28 kidneys. Microscopically, the parenchymal changes were minimal. In vivo study of the use of the single under-table head revealed that 5 of 6 kidneys had large subcapsular hematomas at both anterior and posterior surfaces and on coronal section extending into the parenchyma. Microscopically, the changes were significant.

Conclusions

Synchronous twin pulse shock waves induced minimal damage compared with single pulse standard shock waves. Of note, even after 3000 twin pulses (ie, a total of 6000 shock waves), the renal damage remained minimal.

Le texte complet de cet article est disponible en PDF.

Plan


 This work was supported by Midwest Stone Institute, research endowment to the Division of Urology, Washington University, St. Louis, Missouri.


© 2003  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 62 - N° 5

P. 964-967 - novembre 2003 Retour au numéro
Article précédent Article précédent
  • Improved sphincter contractility after allogenic muscle-derived progenitor cell injection into the denervated rat urethra
  • Tracy W Cannon, Ji Youl Lee, George Somogyi, Ryan Pruchnic, Christopher P Smith, Johnny Huard, Michael B Chancellor
| Article suivant Article suivant
  • Edward Lawrence Keyes: a pivotal early specialist in modern genitourinary surgery
  • Emily B Smith, E.D Vaughan, Edward S Belt, David A Bloom

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.