S'abonner

Quantitative myocardial contrast echocardiography for prediction of Thrombolysis In Myocardial Infarction flow in acute myocardial infarction - 26/08/11

Doi : 10.1016/j.amjcard.2004.02.010 
Stuart Moir, MBBS a, Brian Haluska, MS a, Dominic Leung, MBBS, PhD a, Richard Lim, MD a, Paul Garrahy, MBBS a, Thomas H Marwick, MBBS, PhD a, *
a University of Queensland, Brisbane, Australia 

*Address for reprints: Thomas H. Marwick, MBBS, PhD, University of Queensland, Department of Medicine, Princess Alexandra Hospital, Ipswich Road, Brisbane, Qld 4012, Australia.

Abstract

Clinical evaluation of arterial patency in acute ST-elevation myocardial infarction (STEMI) is unreliable. We sought to identify infarction and predict infarct-related artery patency measured by the Thrombolysis In Myocardial Infarction (TIMI) score with qualitative and quantitative intravenous myocardial contrast echocardiography (MCE). Thirty-four patients with suspected STEMI underwent MCE before emergency angiography and planned angioplasty. MCE was performed with harmonic imaging and variable triggering intervals during intravenous administration of Optison. Myocardial perfusion was quantified offline, fitting an exponential function to contrast intensity at various pulsing intervals. Plateau myocardial contrast intensity (A), rate of rise (β), and myocardial flow (Q = A × β) were assessed in 6 segments. Qualitative assessment of perfusion defects was sensitive for the diagnosis of infarction (sensitivity 93%) and did not differ between anterior and inferior infarctions. However, qualitative assessment had only moderate specificity (50%), and perfusion defects were unrelated to TIMI flow. In patients with STEMI, quantitatively derived myocardial blood flow Q (A × β) was significantly lower in territories subtended by an artery with impaired (TIMI 0 to 2) flow than those territories supplied by a reperfused artery with TIMI 3 flow (10.2 ± 9.1 vs 44.3 ± 50.4, p = 0.03). Quantitative flow was also lower in segments with impaired flow in the subtending artery compared with “normal” patients with TIMI 3 flow (42.8 ± 36.6, p = 0.006) and all segments with TIMI 3 flow (35.3 ± 32.9, p = 0.018). An receiver-operator characteristic curve derived cut-off Q value of <11.3, representing impaired myocardial flow, was 73% sensitive and 67% specific for TIMI <3 flow at angiography. Thus, qualitative MCE identifies patients with STEMI but provides no information regarding infarct-related artery patency, whereas quantitative MCE can predict impaired flow in patients with acute STEMI.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported in part by grants from the National Heart Foundation of Australia, Melbourne, Australia; and the Princess Alexandra Hospital Foundation, Brisbane, Australia.


© 2004  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 93 - N° 10

P. 1212-1217 - mai 2004 Retour au numéro
Article précédent Article précédent
  • Usefulness of myocardial contrast echocardiography in predicting collateral blood flow in the presence of a persistently occluded acute myocardial infarction–related coronary artery
  • Rajesh Janardhanan, Leah Burden, Roxy Senior
| Article suivant Article suivant
  • Care concordant with guidelines predicts decreased long-term mortality in patients with unstable angina pectoris and non–ST-Elevation myocardial infarction
  • Larry A Allen, Christopher J O'Donnell, Robert P Giugliano, Carlos A Camargo, Donald M Lloyd-Jones

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.