Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes - 26/08/11

Doi : 10.1016/S0002-9394(02)02077-9 
Harmohina Bagga, MD a, David S Greenfield, MD a, , William Feuer, MS a, Robert W Knighton, PhD a
a Department of Ophthalmology, University of Miami School of Medicine, Bascom Palmer Eye Institute, Miami, Florida, USA 

*Inquiries to David S. Greenfield, MD, Bascom Palmer Eye Institute, 7108 Fairway Dr, Suite 340, Palm Beach Gardens, FL, USA 33418; fax: (561) 515-1598

Abstract

Purpose

To evaluate the relationship between visual function and retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry with variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT).

Design

Cross-sectional analysis of normal and glaucomatous eyes in a tertiary care academic referral practice.

Methods

A commercial GDx nerve fiber analyzer was modified to enable the measurement of corneal polarization axis and magnitude so that compensation for corneal birefringence was eye specific. Complete examination, SLP with fixed corneal compensation (FCC) and variable corneal compensation (VCC), optical coherence tomography (OCT) imaging of the peripapillary RNFL, and automated achromatic perimetry were performed in all subjects. Exclusion criteria were visual acuity less than 20/40, diseases other than glaucoma, and unreliable perimetry.

Results

Fifty-nine patients (59 eyes; 29 normal, 30 glaucomatous) were enrolled (mean age, 56.7 ± 20.3 years, range, 20–91). All eyes with glaucoma had associated visual field loss (average mean defect, −8.4 ± 5.8 dB). Using SLP-FCC, nine of 12 retardation parameters (75%) were significantly less in glaucomatous eyes. Using SLP-VCC, 11of 12 retardation parameters (92%) were significantly less in glaucomatous eyes. Multiple regression models constructed for each retardation parameter with visual field demonstrated that the following VCC parameters were statistically significant whereas FCC parameters were not: ellipse average (FCC, P = .28, VCC, P = .001), superior average (FCC, P = .38, VCC, P < .001), inferior average (FCC, P = .10, VCC, P = .008), average thickness (FCC, P = .30, VCC, P = .031), and superior integral (FCC, P = .43, VCC, P = .001). Similar results were obtained for multiple regression models constructed with OCT-derived RNFL thickness: ellipse average (FCC, P = .99, VCC, P = .002), superior average (FCC, P = .90, VCC, P < .001), inferior average (FCC, P = .61, VCC, P = .007), and superior integral (FCC, P = .92, VCC, P < .001).

Conclusions

Compared with fixed compensation, mean-based SLP parameters generated with SLP-VCC have greater correlation with visual function and RNFL thickness assessments obtained with OCT.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported in part by the New York Community Trust, New York, New York; a grant from Mr Barney Donnelley, Palm Beach, Florida; and National Institutes of Health Grant R01-EY08684, Bethesda, Maryland. Doctor Greenfield is a member of the Scientific Advisory Board, Laser Diagnostic Technology, San Diego, California.
 InternetAdvance publication at ajo.com Jan 6, 2003.


© 2003  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 135 - N° 4

P. 521-529 - avril 2003 Retour au numéro
Article précédent Article précédent
  • Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography
  • Akiyasu Kanamori, Makoto Nakamura, Michael F.T Escano, Ryu Seya, Hidetaka Maeda, Akira Negi
| Article suivant Article suivant
  • An improved technique of eye drop self-administration for patients with limited vision
  • Robert Ritch, Karim N. Jamal, Rabi̇a Gürses-Özden, Jeffrey M. Liebmann

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.