S'abonner

Shortterm and longterm visual and astigmatic results of an opposing 10-0 nylon double running suture technique for penetrating keratoplasty - 28/08/11

Doi : 10.1016/j.jamcollsurg.2003.07.016 
Arlene MT Dolorico, MD *, , Ramin Tayyani, MD, MSPH *, Hung V Ong, MD *, Ronald N Gaster, MD, FACS *,
* Department of Ophthalmology (Dolorico, Tayyani, Ong, Gaster), University of California, Irvine, Irvine, CA, USA 
 Long Beach VA Medical Center (Dolorico, Gaster), Long Beach, CA, USA 

*Correspondence address: Ronald N Gaster, MD, Department of Ophthalmology, UCI Medical Plaza, Irvine, CA 92697, USA.

Abstract

Background

In ophthalmic surgery, corneal transplantation (penetrating keratoplasty) may be employed when the clarity of the cornea has been significantly compromised by conditions such as scarring, edema, and variable corneal thickness. Irregularities in corneal curvature can occur postoperatively. This astigmatism is of concern, because it can impair visual acuity despite an otherwise good surgical result. Different suturing techniques have been developed to minimize astigmatism. The purpose of this study was to evaluate an opposing 10-0 nylon double running suture technique for penetrating keratoplasty.

Study design

A retrospective study was undertaken of 91 records of patients who underwent penetrating keratoplasty performed by one surgeon (RNG). This represents 54.8% of 166 consecutive cases. Every eye with an opposing double running suture and a 1- to 3-month postsuture removal followup was selected and evaluated for best corrected visual acuity and astigmatism, excluding eyes that developed graft failure or corneal ulcer or that had lack of adequate followup. The cases were divided into five groups by preoperative diagnosis: pseudophakic bullous keratopathy (n = 43), aphakic bullous keratopathy (n = 5), keratoconus (n = 17), Fuchs dystrophy (n = 12), and miscellaneous (n = 14). The mean standard followup period was 13.7 months after penetrating keratoplasty. Thirty percent of the eyes had an extensive followup, with a mean of 33 months after penetrating keratoplasty.

Results

Eighty-two percent of the patients had a significant improvement of their visual acuity postoperatively, defined by a five-line improvement of best corrected visual acuity or a best corrected visual acuity of 20/40 or better. The mean astigmatic keratometric reading was 3.98 diopters, with a manifest refraction cylinder of 3.42 diopters at the 1- to 3-month postsuture removal visit. This study also shows that there is no statistically significant change in keratometric astigmatism or manifest refraction cylinder from the 1- to 3-month postsuture removal measurements to the more extensive followup of 18 to 66 months after penetrating keratoplasty (p > 0.10).

Conclusions

This suture technique allows for excellent longterm stability of the wound with visual and astigmatic results that are comparable to those of previous studies. The use of the opposing double running suture is a viable alternative to some of the other widely used techniques and may be considered more stable and secure.

Le texte complet de cet article est disponible en PDF.

Plan


 No competing interests declared.
This study was supported by a grant from the Long Beach VA Medical Center Research Foundation.


© 2003  American College of Surgeons. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 197 - N° 6

P. 991-999 - décembre 2003 Retour au numéro
Article précédent Article précédent
  • What's new in orthopaedic surgery
  • Mark R Belsky
| Article suivant Article suivant
  • Comparison of private versus academic practice for general surgeons: a guide for medical students and residents
  • Anneke T Schroen, Michelle R Brownstein, George F Sheldon

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.