The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging - 01/09/11

Doi : 10.1016/S0016-5107(02)70177-6 
Syed G. Shah, MRCP, Jim C. Brooker, MRCP, Christopher B. Williams, FRCP, FRCS, Catherine Thapar, RGN, Noriko Suzuki, MD, Brian P. Saunders, MD
Current affiliations: Wolfson Unit for Endoscopy, St. Mark's Hospital, London, United Kingdom 

Abstract

Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon (p = 0.0041) and time to negotiate the splenic flexure (p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer (p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening. (Gastrointest Endosc 2002;56:195-201.)

Le texte complet de cet article est disponible en PDF.

Plan


 Funding by Trusthouse Charitable Foundation.
 Reprint requests: Dr. Brian P. Saunders, Wolfson Unit for Endoscopy, St. Mark's Hospital, Watford Road, Harrow, Middlesex, London, United Kingdom, HAL 3UJ.


© 2002  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 56 - N° 2

P. 195-201 - août 2002 Retour au numéro
Article précédent Article précédent
  • Minimizing postcolonoscopy abdominal pain by using CO2 insufflation: A prospective, randomized, double blind, controlled trial evaluating a new commercially available CO2 delivery system
  • Katica Sumanac, Ian Zealley, Bruce M. Fox, John Rawlinson, Bruno Salena, John K. Marshall, Giles W. Stevenson, Richard H. Hunt
| Article suivant Article suivant
  • Nifedipine for prevention of post-ERCP pancreatitis: A prospective, double-blind randomized study
  • Frédéric Prat, Juan Amaris, Béatrice Ducot, Muriel Bocquentin, Jacques Fritsch, André Daniel Choury, Gilles Pelletier, Catherine Buffet

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.