Randomized crossover comparison of right atrial appendage pacing versus interatrial septum pacing for prevention of paroxysmal atrial fibrillation in patients with sinus bradycardia - 03/09/11

Doi : 10.1067/mhj.2001.119373 
Luigi Padeletti, MDa, Paolo Pieragnoli, MDa, Cristina Ciapetti, MDa, Andrea Colella, MDa, Nicola Musilli, MDa, Maria Cristina Porciani, MDa, Renato Ricci, MDb, Carlo Pignalberi, MDb, Massimo Santini, MDb, Andrea Puglisi, MDc, Paolo Azzolini, MDc, Andrea Spampinato, MDd, Moira Martelli, MDd, Alessandro Capucci, MDe, Giuseppe Boriani, MDf, GianLuca Botto, MDg, Alessandro Proclemer, MDh
Florence, Rome, Piacenza, Bologna, Como, and Udine, Italy 
From the aInstitute of Internal Medicine and Cardiology, University of Florence, Florence, the bS. Filippo Hospital, the cFatebenefratelli Hospital, and the dVilla Tiberia Hospital, Rome, the eGeneral Hospital, Piacenza, the fGeneral Hospital, Bologna, the gS. Anna Hospital, Como, and the hMaria della Misericordia Hospital, Udine, Italy 

Abstract

Background New atrial pacing techniques and overdrive pacing algorithms have been introduced to prevent atrial fibrillation. This study was designed to test the hypotheses that (1) interatrial septum pacing (IASP) at the triangle of Koch would be more effective than right atrial appendage pacing (RAAP) in preventing paroxysmal atrial fibrillation (PAF) in patients with sinus bradycardia and (2) an algorithm (CAP) designed to achieve constant atrial capture would increase the efficacy of rate-responsive atrial pacing. Methods We studied 46 patients with PAF and sinus bradycardia implanted with a DDD(R) (Medtronic Thera) pacemaker. Twenty-four patients (6.0 ± 10.1 PAF episodes/month within 3 months before study) were randomized to RAAP and 22 patients (5.4 ± 7.1, not significant) to IASP. Within each arm 2 randomized crossover periods of CAP-OFF and CAP-ON function were programed. Results The PAF episodes per month significantly decreased in the RAAP (CAP-OFF: 2.1 ± 4.2, P < .05; CAP-ON: 1.9 ± 3.8, P < .05) and in the IASP group (CAP-OFF: 0.2 ± 0.5, P < .05; CAP-ON: 0.2 ± 0.5, P < .05). Values were significantly lower in the IASP group than in the RAAP group in both CAP-OFF (0.2 ± 0.5 vs 2.1 ± 4.2, P < .05) and CAP-ON (0.2 ± 0.5 vs 1.9 ± 3.8, P < .05) conditions. PAF burden was significantly lower in the IASP than in the RAAP group in CAP-OFF (47 ± 84 min/d vs 140 ± 217, P < .05) and in CAP-ON (41 ± 72 vs 193 ± 266, P < .05) conditions. No differences were observed within each arm in PAF burden between the 2 crossover CAP programing periods. Conclusions Rate-adaptive IASP at the triangle of Koch is more effective than RAAP in preventing PAF in patients with sinus bradycardia. In our sample of patients no additional clinical benefit is furnished by the CAP algorithm. (Am Heart J 2001;142:1047-55.)

Le texte complet de cet article est disponible en PDF.

Plan


 Reprint requests: Luigi Padeletti, MD, Institute of Internal Medicine and Cardiology, University of Florence, Viale Morgagni 85, 50134 Florence, Italy. E-mail: elettrofisiologia@dfc.unifi.it


© 2001  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 142 - N° 6

P. 1047-1055 - décembre 2001 Retour au numéro
Article précédent Article précédent
  • Validation of a specific activity questionnaire to estimate exercise tolerance in patients referred for exercise testing
  • Jonathan Myers, David Bader, Rupa Madhavan, Victor Froelicher
| Article suivant Article suivant
  • Changes in vasoconstrictive hormones, natriuretic peptides, and left ventricular remodeling soon after anterior myocardial infarction
  • Michel White, Jean L. Rouleau, Christian Hall, Malcolm Arnold, Francois Harel, Pierre Sirois, Sally Greaves, Scott Solomon, Umed Ajani, Robert Glynn, Charles Hennekens, Marc Pfeffer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.