Accuracy of glaucoma detection with frequency-doubling perimetry - 05/09/11

Doi : 10.1016/S0002-9394(00)00354-8 
John R Trible, MD a, , Richard O Schultz, MD a, James C Robinson, MD a, Terri L Rothe a
a Eye Institute, Medical College of Wisconsin, Milwaukee, Wisconsin, USA 

*Reprint requests to John R. Trible, MD, 309 E Church St, Marshalltown, IA 50158; fax: (515) 752-7420

Abstract

PURPOSE: To determine the accuracy of glaucoma detection by frequency-doubling perimetry.

METHODS: Stereoview optic nerve photographs, visual field examination, intraocular pressure measurements, medical and ocular history, and a screening and full threshold frequency-doubling perimetry examination were performed in a prospective study of consecutive subjects. Inclusion criteria included age of 45 years or older, absence of ocular disease other than glaucoma, cataract, or mild drusen, and Snellen visual acuity of 20/60 or better. A total of 125 eyes in 102 glaucoma subjects and 95 eyes of 95 normal subjects were included. Each eye was classified as “normal,” “glaucoma,” or “uncertain” by each of three ophthalmologists on the basis of all available clinical information with the exception of frequency-doubling perimetry results. Those in the glaucoma group were subclassified as having early (n = 51), moderate (n = 42), or severe (n = 32) glaucoma on the basis of automated Humphrey visual field criteria. In the glaucoma group, two eyes from a subject were allowed to be included (23 of 102 subjects) if they differed in level of damage because they were never analyzed within the same statistical analysis.

RESULTS: Several diagnostic algorithms were evaluated. Algorithms based on the most depressed single point, pair of adjacent points, and cluster of three points performed nearly identically. For the screening test, if any abnormality was identified, specificity was 95%, whereas sensitivity was 39%, 86%, and 100% for early, moderate, and severe glaucoma, respectively. For the full threshold test, with at least one point depressed to the P < 0.5% level, specificity measured 91%, whereas sensitivity was 35%, 88%, and 100% for early, moderate, and severe glaucoma, respectively. The two global indices, mean deviation and pattern standard deviation, were also evaluated and were generally less accurate.

CONCLUSION: Frequency-doubling perimetry, which is rapid and easily administered, is effective at detecting moderate and severe disease and appears well suited for glaucoma screening.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported in part by Ann and Joseph F. Heil, Jr, the R. D. and Linda Peters Foundation, Milwaukee, Wisconsin, and Research to Prevent Blindness, Inc, New York, New York.


© 2000  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 129 - N° 6

P. 740-745 - juin 2000 Retour au numéro
Article précédent Article précédent
  • Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser doppler flowmetry
  • Kiyoshi Yaoeda, Motohiro Shirakashi, Shigeo Funaki, Haruko Funaki, Tomoko Nakatsue, Haruki Abe
| Article suivant Article suivant
  • Epithelial ingrowth after laser in situ keratomileusis
  • Mathew Y Wang, Robert K Maloney

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.