S'abonner

Prospective comparative evaluation of video US endoscope - 08/09/11

Doi : 10.1016/S0016-5107(99)70284-1 
Amitabh Chak, MD, Gerard Isenberg, MD, Shawn Mallery, MD, Jacques Van Dam, MD, PhD, Gregory S. Cooper, MD, Michael V. Sivak, MD
Cleveland, Ohio, and Boston, Massachusetts 
From the Divisions of Gastroenterology, University Hospitals of Cleveland, Cleveland, Ohio, and Brigham and Women's Medical Center, Boston, Massachusetts 

Abstract

Background: Limitations in the technical capabilities of the fiberoptic echoendoscope often necessitate concurrent diagnostic endoscopy at the time of an endosonographic (EUS) examination. Our aim was to determine whether a new video echoendoscope would allow the performance of EUS without diagnostic endoscopy. Methods: EUS examinations on all patients at two centers were initiated with a fiberoptic echoendoscope (period of 5 weeks) or a video echoendoscope (period of 6 weeks). Note was made of need for concurrent diagnostic endoscopy. The endosonographer also rated the mechanical, optical, and sonographic performance of the video instrument using a 9-point comparative scale (1 = much worse, 5 = equal to, and 9 = much better than fiberoptic echoendoscope). Results: A total of 103 patients including 40 and 28 with mural lesions and 22 and 15 with retroperitoneal lesions were examined with the fiberoptic and video echoendoscopes, respectively. Mean values for parameters rating the video echoendoscope's mechanical performance ranged between 5.0 and 5.9, optical performance ranged between 6.6 and 7.5, and sonographic performance ranged between 4.6 and 4.9. Concurrent diagnostic endoscopy was required less frequently when patients with mural lesions (18% vs. 70%, p < 0.005) or patients with retroperitoneal lesions (0% vs. 14%, p = no significance) were examined with the video echoendoscope compared with the fiberoptic echoendoscope. Conclusions: Moderately improved optics and slightly better mechanical characteristics of the new video echoendoscope allow the performance of EUS without concurrent diagnostic endoscopy in the majority of patients. (Gastrointest Endosc 1999;49:695-9.)

Le texte complet de cet article est disponible en PDF.

Plan


 Supported in part by the Wilson Cook Endoscopic Research Scholar Award, 1997-98 (A.C.).
 Reprint requests: Amitabh Chak, MD, University Hospitals of Cleveland, 11100 Euclid Ave., Cleveland, OH 44106-1736.
 37/1/95776


© 1999  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 49 - N° 6

P. 695-699 - juin 1999 Retour au numéro
Article précédent Article précédent
  • Risk of sedation for upper GI endoscopy exacerbating subclinical hepatic encephalopathy in patients with cirrhosis
  • Nimer Assy, Barry G. Rosser, Gordon R. Grahame, Gerald Y. Minuk
| Article suivant Article suivant
  • Interobserver and intraobserver variation in endoscopic assessment of GERD using the “Los Angeles” classification
  • Motoyasu Kusano, Kyoko Ino, Takuro Yamada, Osamu Kawamura, Munetoshi Toki, Tsuneo Ohwada, Kazuma Kikuchi, Tohko Shirota, Masayuki Kimura, Makoto Miyazaki, Kazumi Nakamura, Sae Igarashi, Michiko Tomizawa, Tatsuya Tamura, Toshikazu Sekiguchi, Masatomo Mori

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.